Evaluation of a new method for determining tracheal tube length in children
Authors:
Open Access
- 1 December 1995
- journal article
- Published by Wiley in Anaesthesia
- Vol. 50 (12) , 1050-1052
Abstract
Summary: Most paediatric tracheal tubes are marked in centimetres from the tip. In 105 children, nasotracheal tube length was set at the level of the vocal cords such that all 3.0 and 3.5 mm internal diameter tubes were placed with the 3 cm mark at the cords, all 4.0 and 4.5 tubes were set at 4 cm at the cords and all 5.0 and 5.5 tubes were set at 5 cm at the cords. Subsequent chest X ray showed that 79% of the tracheal tubes were in the ideal midtracheal position, one tube was marginally short and 20% of the tubes were marginally long. Neither bronchial intubation nor accidental extubation occurred in any subject. This is an effective method to determine tracheal tube length which may be used for both oral and nasal intubation.Keywords
This publication has 9 references indexed in Scilit:
- Tracheal Intubation in ChildrenAnesthesia & Analgesia, 1988
- ESTIMATION OF NASOTRACHEAL TUBE LENGTH IN INFANTS AND CHILDRENBritish Journal of Anaesthesia, 1987
- Dimensions of the growing trachea related to age and genderAmerican Journal of Roentgenology, 1986
- PAEDIATRIC ANAESTHETIC EQUIPMENTBritish Journal of Anaesthesia, 1985
- A pre-formed paediatric orotracheal tube design based on anatomical measurementsCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1982
- Endotracheal tube displacement in the newborn infantThe Journal of Pediatrics, 1976
- Alteration of endotracheal tube position Flexion and extension of the neckCritical Care Medicine, 1976
- A New and Safe Method to Control the Depth of Endotracheal Intubation in NeonatesPediatrics, 1974
- Endotracheal tube position in the infantThe Journal of Pediatrics, 1971