Osseointegrated endosseous implants are widely used for the rehabilitation of completely and partially edentulous patients, being the final prosthodontic treatment more predictable and the failures extremely infrequent. A case of fracture of an endosseous dental implant, replacing the maxillary first molar, occurring in a middle-age woman, 5 years after placement is reported. The difficult management of this rare complication of implant dentistry together with the following rehabilitation is described. Additionally, the authors performed an accurate analysis of the removed fractured implant both by the stereomicroscope and by the confocal laser scanning microscope. The fractured implant showed the typical signs of a fatigue-induced fracture in the coronal portion of the implant together with numerous micro-fractures in the apical one. Three dimensional imaging performed by confocal laser scanning microscope led easily to a diagnosis of "fatigue fracture" of the implant. The biomechanical mechanism of implant fractures when overstress of the implant components due to bending overload is discussed. When a fatigue-induced fracture of an dental implant occurs in presence of bending overload, the whole implant suffers a deformation that is confirmed by the alterations (micro-fractures) of the implant observable also in the osseointegrated portion that is easily appraisable by the use of stereomicroscope and confocal laser scanning microscope without preparation of the sample.Keywords
This publication has 19 references indexed in Scilit:
- Fracture mechanisms of retrieved titanium screw thread in dental implantBiomaterials, 2002
- A study on the fracture strength of implant-supported restorations using milled ceramic abutments and all-ceramic crowns.2002
- Influence of bicortical or monocortical anchorage on maxillary implant stability: a 15-year retrospective study of Brånemark System implants.2000
- Survival of the Brånemark implant in partially edentulous jaws: a 10-year prospective multicenter study.1999
- Histologic Observations on 230 Retrieved Dental Implants: 8 Years' Experience (1989–1996)Journal of Periodontology, 1998
- Complications and maintenance requirements of implant-supported prostheses provided in a UK dental hospitalBritish Dental Journal, 1997
- Implant treatment in partially edentulous patients: a report on prostheses after 3 years.1994
- A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspectsThe Journal of Prosthetic Dentistry, 1992
- The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part III: Problems and complications encounteredThe Journal of Prosthetic Dentistry, 1990
- A 15-year study of osseointegrated implants in the treatment of the edentulous jawInternational Journal of Oral Surgery, 1981