Descemet-stripping automated endothelial keratoplasty: a successful alternative to repeat penetrating keratoplasty
Authors:
- 14 January 2011
- journal article
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 39 (3) , 195-200
Abstract
Although Descemet-stripping automated endothelial keratoplasty has replaced penetrating keratoplasty for primary treatment of endothelial disorders, many patients have already undergone penetrating keratoplasty. It is unclear when repeat penetrating keratoplasty is necessary or when endothelial keratoplasty may restore clarity to a failed graft. Retrospective case series of patients undergoing Descemet-stripping automated endothelial keratoplasty after penetrating keratoplasty by three surgeons at an academic tertiary care centre. Eight patients with Descemet-stripping automated endothelial keratoplasty after penetrating keratoplasty from 2006 to 2009. Microkeratome-prepared Descemet-stripping automated endothelial keratoplasty donor tissue was used. In seven cases, the penetrating keratoplasty bed was neither stripped nor scraped, and in one, scraping only was performed. Preoperative and 6-month postoperative best-corrected visual acuities in logMAR (logarithm of the minimum angle of resolution). The average pre-Descemet-stripping automated endothelial keratoplasty best-corrected visual acuity was 1.375, and the average best-corrected visual acuity 6months postoperatively was logMAR 1.0, a 2.5-fold improvement in the minimum angle of resolution (P=0.22). Seven of the eight patients showed an improvement in best-corrected visual acuity, and one patient had failure of Descemet-stripping automated endothelial keratoplasty and required penetrating keratoplasty. Five had a postoperative event: one had a gap that resolved spontaneously, three required rebubblings (injections of air only without otherwise repositioning the graft), and one experienced graft failure. Descemet-stripping automated endothelial keratoplasty can successfully rescue a prior penetrating keratoplasty, even with a fairly high detachment rate. Given these favourable visual outcomes, further study of this promising strategy is justified.Keywords
This publication has 13 references indexed in Scilit:
- Descemet's Stripping Endothelial Keratoplasty: Safety and OutcomesOphthalmology, 2009
- Retrospective Contralateral Study Comparing Descemet Stripping Automated Endothelial Keratoplasty With Penetrating KeratoplastyCornea, 2009
- Comparison of Posterior Lamellar Keratoplasty Techniques to Penetrating KeratoplastyOphthalmology, 2008
- Donor dislocation after DSAEK for a failed corneal graftBritish Journal of Ophthalmology, 2008
- Corneal Transplant Rejection Rate and Severity After Endothelial KeratoplastyCornea, 2007
- Descemet Stripping and Automated Endothelial Keratoplasty (DSAEK) in Eyes With Failed Penetrating KeratoplastyCornea, 2007
- Endothelial Keratoplasty to Restore Clarity to a Failed Penetrating GraftCornea, 2006
- Descemet-Stripping Automated Endothelial KeratoplastyCornea, 2006
- Deep Lamellar Endothelial Keratoplasty in the First United States PatientsCornea, 2001
- Graft failure after penetrating keratoplastySurvey of Ophthalmology, 1990