Quantitative Measurement of Immunoglobulins and Free Light Chains Using Mass Spectrometry
- 28 July 2015
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 87 (16) , 8268-8274
Abstract
Serum free light chain (sFLC) assays are well established in the diagnosis and monitoring of plasma cell disorders. However, current FLC immunoassays are subject to several analytical issues, which results in a lack of harmonized results. To facilitate sFLC standardization, we investigated the strengths and limitations of mass spectrometry as a novel technological platform for sFLC quantification. Stable isotope labeled reference peptides are added to serum samples for quantitation by selected reaction monitoring (SRM). The use of redundant peptide sets allows for quality control measures during data analysis. Measurements on serum provide information on intact immunoglobulins, but depletion of these intact molecules from the sera during sample processing permits the quantitation of sFLC. sFLC concentrations measured with SRM were comparable to those obtained by nephelometry and showed excellent linearity (r(2) > 0.99). In samples with high levels of sFLC, SRM data was more consistent with serum protein electrophoresis than nephelometric data and SRM is unaffected by antigen excess. The lower limits of quantitation were 3.8 and 2.7 mg/L for κ and λ sFLC. Errors due to polymorphic sequences were prevented by comparison of redundant peptide pairs. The application of stable isotope labeling combined with SRM can overcome many of the current potential analytical issues of sFLC analysis. We describe which hurdles still need to be taken to make SRM a robust and more accurate method for sFLC measurements.Keywords
This publication has 34 references indexed in Scilit:
- Overestimation of Serum κ Free Light Chain Concentration by ImmunonephelometryClinical Chemistry, 2010
- Skyline: an open source document editor for creating and analyzing targeted proteomics experimentsBioinformatics, 2010
- Quantitation of Serum Monoclonal Proteins: Relationship between Agarose Gel Electrophoresis and ImmunonephelometryClinical Chemistry, 2009
- International Myeloma Working Group guidelines for serum-free light chain analysis in multiple myeloma and related disordersLeukemia, 2008
- Quantitative Assessment of Serum and Urinary Polyclonal Free Light Chains in Patients with Chronic Kidney DiseaseClinical Journal of the American Society of Nephrology, 2008
- IMGT(R), the international ImMunoGeneTics information system(R)Nucleic Acids Research, 2008
- International uniform response criteria for multiple myelomaLeukemia, 2006
- Heavy chain diseasesBest Practice & Research Clinical Haematology, 2005
- The Human Genome Browser at UCSCGenome Research, 2002
- BLAT—The BLAST-Like Alignment ToolGenome Research, 2002