Three-Dimensional Assessments of Intraocular Lens Stability With High-Speed Swept-Source Optical Coherence Tomography
Authors:
- Xixia DingXDXixia Ding
- Qinmei WangQWQinmei Wang
- Linfeng XiangLXLinfeng Xiang
- Pingjun ChangPCPingjun Chang
- Shenghai HuangSHShenghai Huang
- Yun-E ZhaoYZYun-E Zhao
- 1 June 2020
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 36 (6) , 388-394
Abstract
PURPOSE: To evaluate the effect of intraocular lens (IOL) optic overlapping on IOL stability and to determine the relationship between the capsulorhexis and IOL movement with the three-dimensional method of swept-source optical coherence tomography (SS-OCT). METHODS: This study identified patients with age-related cataracts and divided them into two groups according to their anterior capsule and IOL optic relationship: total anterior capsule overlap (360°) and partial anterior capsule overlap (< 360°). Standard SS-OCT radial scanning was performed in all eyes at 1 day, 1 week, 1 month, and 3 months after cataract surgery, respectively. The obtained photographs were used for the postoperative position measurements of capsulorhexis and IOL after three-dimensional reconstruction. RESULTS: This study included 46 eyes of 34 patients: total overlap group (n = 29) and partial overlap group (n = 17). The postoperative aqueous depth significantly decreased in the first week after surgery ( P < .001). The IOL tilt was greater in the partial overlap group than that in the total overlap group ( P = .014). The IOL moved significantly in the first week postoperatively (both P < .001). IOL decentration in the x-axis was greater in the partial overlap group than that in the total overlap group ( P = .024). The IOL and capsulorhexis both moved sharply in the first week (both P < .05). The IOL moved consistently with the capsulorhexis in the 3 months after surgery (all P > .05). CONCLUSIONS: The total overlap group showed better IOL centrality and stability. IOL movement may be driven by capsular bag contraction and fibrosis. Thus, it was demonstrated that postoperative IOL position and IOL performance were closely linked with proper size of central continuous curvilinear capsulorhexis. [ J Refract Surg . 2020;36(6):388–394.]Keywords
This publication has 34 references indexed in Scilit:
- Effect of Decentration on the Optical Performance in Multifocal Intraocular LensesOphthalmologica, 2012
- Anterior chamber depth and change in axial intraocular lens position after cataract surgery with primary posterior capsulorhexis and posterior optic buttonholingJournal of Cataract & Refractive Surgery, 2008
- Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imagingJournal of Cataract & Refractive Surgery, 2007
- Tilt and Decentration of Three-Piece Foldable High-Refractive Silicone and Hydrophobic Acrylic Intraocular Lenses With 6-mm Optics in an Intraindividual ComparisonAmerican Journal of Ophthalmology, 2005
- Ocular Higher-Order Wavefront Aberration Caused by Major Tilting Of Intraocular LensAmerican Journal of Ophthalmology, 2005
- Influence of intraocular lens tilt and decentration on wavefront aberrationsJournal of Cataract & Refractive Surgery, 2004
- Effect of optic edge design and haptic angulation on postoperative intraocular lens position changeJournal of Cataract & Refractive Surgery, 2004
- Factors leading to lens implant decentration and exchangeEye, 2000
- Tilt and decentration of bag-fixated intraocular lenses: A comparative study between capsulorhexis and envelope techniquesDocumenta Ophthalmologica, 1994
- Intraocular lens tilt and decentration: A concern for contemporary IOL designsNepalese Journal of Ophthalmology, 1970