Sensitivity distribution simulations of surface electrode configurations for electrical impedance myography
- 5 January 2017
- journal article
- research article
- Published by Wiley in Muscle & Nerve
- Vol. 56 (5) , 887-895
Abstract
Introduction: Surface‐based electrical impedance myography (EIM) is sensitive to muscle condition in neuromuscular disorders. However, the specific contribution of muscle to the obtained EIM values is unknown.Methods: We combined theory and the finite element method to calculate the electrical current distribution in a 3‐dimensional model using different electrode array designs and subcutaneous fat thicknesses (SFTs). Through a sensitivity analysis, we decoupled the contribution of muscle from other surrounding tissues in the measured surface impedance values.Results: The contribution of muscle to surface EIM values varied greatly depending on the electrode array size and the SFT. For example, the contribution of muscle with 6‐mm SFT was 8% for a small array compared with 32% for a large array.Conclusions: The approach presented can be employed to inform the design of robust EIM electrode configurations that maximize the contribution of muscle across the disease and injury spectrum. Muscle Nerve 56: 887–895, 2017Keywords
Funding Information
- National Institutes of Health (K24 NS060951)
This publication has 32 references indexed in Scilit:
- Electrical impedance myography for monitoring motor neuron loss in the SOD1 G93A amyotrophic lateral sclerosis ratClinical Neurophysiology, 2011
- Characterizing spinal muscular atrophy with electrical impedance myographyMuscle & Nerve, 2010
- Experimental validation of a method for removing the capacitive leakage artifact from electrical bioimpedance spectroscopy measurementsMeasurement Science and Technology, 2010
- Measurement errors in multifrequency bioelectrical impedance analyzers with and without impedance electrode mismatchPhysiological Measurement, 2009
- Sources of error in bioimpedance spectroscopyPhysiological Measurement, 1998
- The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissuesPhysics in Medicine & Biology, 1996
- The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHzPhysics in Medicine & Biology, 1996
- The dielectric properties of biological tissues: I. Literature surveyPhysics in Medicine & Biology, 1996
- Quantitative in vivo measurements of inner ear tissue resistivities. I. In vitro characterizationIEEE Transactions on Biomedical Engineering, 1993
- The four-electrode resistivity technique in anisotropic media: theoretical analysis and application on myocardial tissue in vivoIEEE Transactions on Biomedical Engineering, 1993