Techniques of Frameless Robot-Assisted Deep Brain Stimulation and Accuracy Compared with the Frame-Based Technique
Open Access
- 11 July 2022
- journal article
- research article
- Published by MDPI AG in Brain Sciences
- Vol. 12 (7) , 906
Abstract
Background: Frameless robot-assisted deep brain stimulation (DBS) is an innovative technique for leads implantation. This study aimed to evaluate the accuracy and precision of this technique using the Sinovation SR1 robot. Methods: 35 patients with Parkinson’s disease who accepted conventional frame-based DBS surgery (n = 18) and frameless robot-assisted DBS surgery (n = 17) by the same group of neurosurgeons were analyzed. The coordinate of the tip of the intended trajectory was recorded as xi, yi, and zi. The actual position of lead implantation was recorded as xa, ya, and za. The vector error was calculated by the formula of √(xi − xa)2 + (yi − ya)2 + (zi − za)2 to evaluate the accuracy. Results: The vector error was 1.52 ± 0.53 mm (range: 0.20–2.39 mm) in the robot-assisted group and was 1.77 ± 0.67 mm (0.59–2.98 mm) in the frame-based group with no significant difference between two groups (p = 0.1301). In 10.7% (n = 3) frameless robot-assisted implanted leads, the vector error was greater than 2.00 mm with a maximum offset of 2.39 mm, and in 35.5% (n = 11) frame-based implanted leads, the vector error was larger than 2.00 mm with a maximum offset of 2.98 mm. Leads were more posterior than planned trajectories in the robot-assisted group and more medial and posterior in the conventional frame-based group. Conclusions: Awake frameless robot-assisted DBS surgery was comparable to the conventional frame-based technique in the accuracy and precision for leads implantation.Keywords
Funding Information
- the National Key R&D Program of China (2020YFC2007304, Z181100001718056, PX2022034)
- the Beijing Municipal Science & Technology Commission (2020YFC2007304, Z181100001718056, PX2022034)
- the Beijing Municipal Administration of Hospitals Incubating Program (2020YFC2007304, Z181100001718056, PX2022034)
This publication has 22 references indexed in Scilit:
- Improving Targeting in Image-Guided Frame-Based Deep Brain StimulationOperative Neurosurgery, 2010
- Surgical Repositioning of Misplaced Subthalamic Electrodes in Parkinson’s Disease: Location of Effective and Ineffective LeadsStereotactic and Functional Neurosurgery, 2009
- REOPERATION FOR SUBOPTIMAL OUTCOMES AFTER DEEP BRAIN STIMULATION SURGERYNeurosurgery, 2008
- Comparison of Accuracy and Precision between Frame-Based and Frameless Stereotactic Navigation for Deep Brain Stimulation Electrode ImplantationStereotactic and Functional Neurosurgery, 2007
- Bilateral deep brain stimulation in Parkinson's disease: a multicentre study with 4 years follow-upBrain, 2005
- Two‐year follow‐up of subthalamic deep brain stimulation in Parkinson's diseaseMovement Disorders, 2003
- Long‐term efficacy of thalamic deep brain stimulation for tremor: Double‐blind assessmentsMovement Disorders, 2002
- Pioneers of Stereotactic NeurosurgeryStereotactic and Functional Neurosurgery, 1992
- Long-term suppression of tremor by chronic stimulation of the ventral intermediate thalamic nucleusThe Lancet, 1991
- A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgeryIEEE Transactions on Biomedical Engineering, 1988