Performance Assessment of PIT VIPER Cables Following Long-Duration Solder Exposure During Manufacturing
Authors:
- Amy WattersonAWAmy Watterson
- Amanda HubbardAHAmanda Hubbard
- Rui Diaz-PachecoRDRui Diaz-Pacheco
- Ashleigh FrancisAFAshleigh Francis
- Robert GranetzRGRobert Granetz
- Theodore GolfinopoulosTGTheodore Golfinopoulos
- Alexey KaplanAKAlexey Kaplan
- Philip MichaelPMPhilip Michael
- Charlie SanabriaCSCharlie Sanabria
- Shane SchweigerSSShane Schweiger
- 15 January 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Abstract
PIT VIPER cables are rare-Earth barium copper oxide (REBCO)-based high-temperature superconducting (HTS) cables developed at the Massachusetts Institute of Technology and Commonwealth Fusion Systems. The cable design consists of a twisted copper former with grooves filled with stacks of REBCO tape, enclosed in a structural jacket. The assembly is then filled with solder in a vacuum pressure impregnation (VPI) process. One side effect of the VPI process, however, is potential damage to the superconductor that reduces its critical current and critical exponent. Damage may result from two mechanisms: prolonged exposure to elevated temperatures, and physical erosion of the copper stabilizer layer of the HTS tape, which leaves parts of the REBCO layer unprotected. In this experiment, the effect of extended time scales ($>2$ h) of flowing tin-lead-based solder exposure on HTS in PIT VIPER cables was tested, exploring for the first time exposure to flowing solder at a time scale that is particularly relevant to large-scale magnet manufacturing. During this study, two experimental samples were manufactured for electrical testing: one 2.5-m-long straight cable and one 20-m-long coiled cable. Each cable was exposed to molten tin-lead solder for 2.5 h during the VPI process, and then, electrically tested in a liquid nitrogen bath. Critical current, $n$-value, and resistance were measured. Critical current is compared to modeled values determined from characterization of the tape used, and degradation is assessed from this comparison. The measured critical current, when tested in a liquid nitrogen bath and under self-field, was uniform within reasonable experimental error. This result derisks solder degradation for the manufacturing of SPARC cable magnets.Keywords
Funding Information
- Commonwealth Fusion Systems and in part by ARPA-E (DE-AR0001259)
This publication has 10 references indexed in Scilit:
- Liquid Nitrogen Superconducting Test Facility at the MIT Plasma Science and Fusion CenterIEEE Transactions on Applied Superconductivity, 2025
- Development of a high current density, high temperature superconducting cable for pulsed magnetsSuperconductor Science and Technology, 2024
- The SPARC Toroidal Field Model Coil ProgramIEEE Transactions on Applied Superconductivity, 2023
- Development of the first non-planar REBCO stellarator coil using VIPER cableSuperconductor Science and Technology, 2023
- Heating-Induced Performance Degradation of REBa2Cu3O7–x Coated Conductors: An Oxygen Out-Diffusion Scenario with Two Activation EnergiesACS Applied Electronic Materials, 2022
- Oxygen out-diffusion in REBCO coated conductor due to heatingSuperconductor Science and Technology, 2021
- Extended-Performance “SuperCurrent” Cryogen-Free Transport Critical-Current Measurement SystemIEEE Transactions on Applied Superconductivity, 2021
- VIPER: an industrially scalable high-current high-temperature superconductor cableSuperconductor Science and Technology, 2020
- Overview of the SPARC tokamakJournal of Plasma Physics, 2020
- Friction Modeling of Flood Flow SimulationsJournal of Hydraulic Engineering, 2018