Significance of independent radon entry rate and air exchange rate assessment for the purpose of radon mitigation effectiveness proper evaluation: case studies
Authors:
Open Access
- 2 April 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 145 (2-3) , 133-137
Abstract
Two new single-family houses identified as insufficient with regard to existing radon barrier efficiency, have been selected for further examination. A complex set of radon diagnosis procedures has been applied in order to localise and quantify radon entry pathways into the indoor environment. Independent assessment of radon entry rate and air exchange rate has been carried out using the continuous indoor radon measurement and a specific tracer gas application. Simultaneous assessment of these key determining factors has turned out to be absolutely crucial in the context of major cause identification of elevated indoor radon concentration.Keywords
This publication has 3 references indexed in Scilit:
- Detection properties of a measuring system for a continuous soil radon concentrations monitoringRadiation Protection Dosimetry, 2008
- Application of the advanced radon diagnosis methods in the indoor building environmentRadiation Protection Dosimetry, 2008
- State-space dynamic model for estimation of radon entry rate, based on Kalman filteringJournal of Environmental Radioactivity, 2007