Development and Validation of a Lateral Flow Device for the Detection of Nicarbazin Contamination in Poultry Feeds
- 24 February 2007
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 55 (6) , 2497-2503
Abstract
Concentrations of the coccidiostat nicarbazin as low as 2 mg/kg in feed can result in violative drug residues arising in poultry liver. A lateral flow device (LFD) was developed for the detection of contaminating concentrations of nicarbazin following solvent extraction of poultry feeds. Test results, as determined by both visual and instrumental measurement, are available within minutes. For 22 feed samples, nicarbazin-free and fortified at 2 mg/kg, the % relative inhibition ranged from 0 to 45% and from 53 to 85%, respectively. Nicarbazin contamination at the critical concentration (2 mg/kg) can be determined in all cases providing the sampling is representative. A wide range of feed samples taken at a mill that incorporated nicarbazin into poultry feed were analyzed. Data generated for these samples by both the LFDs and a mass spectrometric method were compared, and a significant correlation was achieved. Keywords: Lateral flow device; nicarbazin; coccidiostat; poultry; feedKeywords
This publication has 12 references indexed in Scilit:
- Incidence of residues of nine anticoccidials in eggsFood Additives & Contaminants, 2005
- Validation Study of a Lateral-Flow Immunoassay for Detection of Ruminant By-Product Material in Animal Feeds and Feed Ingredients: Performance-Tested MethodSM 0104052005
- Liquid chromatographic tandem mass spectrometric determination of five coccidiostats in poultry eggs and feedJournal of Chromatography B, 2005
- Development of an Immunoassay-Based Lateral Flow Dipstick for the Rapid Detection of Aflatoxin B1 in Pig FeedJournal of Agricultural and Food Chemistry, 2005
- Preliminary evaluation of a lateral flow immunoassay device for screening urine samples for the presence of sulphamethazineJournal of Immunological Methods, 2003
- The production and characterisation of dinitrocarbanilide antibodies raised using antigen mimicsJournal of Immunological Methods, 2002
- Determination of nicarbazin in feeds using liquid chromatography–electrospray mass spectrometryThe Analyst, 1999
- Colloidal carbon particles as a new label for rapid immunochemical test methods: Quantitative computer image analysis of resultsJournal of Biotechnology, 1993
- High-performance liquid chromatographic screening method for low levels of nicarbazin in eggs with off-line cartridge sample clean-upJournal of Chromatography A, 1989
- The Absorption and Excretion of Orally Administered Nicarbazin by ChickensPoultry Science, 1955