Synchrotron X-ray Tomography for 3D Chemical Distribution Measurement of a Flame Retardant and Synergist in a Fiberglass-Reinforced Polymer Blend
- 18 December 2009
- journal article
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 114 (1) , 2-9
Abstract
A fiberglass-reinforced polymer blend with a new-generation flame retardant is studied with multienergy synchrotron X-ray tomography to assess the blend homogeneity. Relative to other composite materials, this sample is difficult to image due to low X-ray contrast between the fiberglass reinforcement and the polymer blend. Also, the glass fibers are only slightly larger than the 3.26 microm voxels and, due to their high concentration, exist as partially aligned bundles in the polymer matrix. To investigate the chemical composition surrounding the glass fibers, new procedures were developed to find and mark the fiberglass and then assess the flame retardant distribution near the fiber bundles. On the basis of the multienergy imaging across Br and Sb K-edges, the absorbance values were converted to volume percent concentrations. Besides the basic question of the successful and stable blending of the flame retardant and synergist within the polymer matrix, we are also interested in precipitation reactions that might concentrate or diminish concentrations in the close vicinity of the fiberglass reinforcement. Thus, a procedure was developed to analyze radial concentrations about selected, well-isolated fiberglass bundles. Overall, the results show a nicely homogeneous system to the level of the tomography resolution, 3.26 microm, with some enhanced concentration near, approximately 20 microm, the fiber bundles.Keywords
This publication has 29 references indexed in Scilit:
- X-ray tomography of whole cellsCurrent Opinion in Structural Biology, 2005
- Three-Dimensional Chemical Analysis with Synchrotron Tomography at Multiple X-ray Energies: Brominated Aromatic Flame Retardant and Antimony Oxide in PolystyreneChemistry of Materials, 2004
- High-Resolution 3D Imaging Microscopy Using Hard X-RaysMRS Bulletin, 2004
- Past and future directions in x‐ray computed tomography (CT)International Journal of Imaging Systems and Technology, 2002
- Geometric Partial Differential Equations and Image Analysis2001
- Synchrotron X-ray Microtomography, Electron Probe Microanalysis, and NMR of Toluene Waste in CementEnvironmental Science & Technology, 2000
- Discrete Tomography1999
- Three‐dimensional reconstruction and modeling of microstructures and microchemistry in geological materialsScanning, 1998
- Medial axis analysis of void structure in three‐dimensional tomographic images of porous mediaJournal of Geophysical Research, 1996
- Synchrotron Computed Microtomography of Porous Media: Topology and TransportsPhysical Review Letters, 1994