A comparison of methods for adaptive sample size adjustment
Authors:
- 20 December 2001
- journal article
- research article
- Published by Wiley in Statistics in Medicine
- Vol. 20 (24) , 3861-3873
Abstract
In fixed sample size designs, precise knowledge about the magnitude of the outcome variable's variance in the planning phase of a clinical trial is mandatory for an adequate sample size determination. Wittes and Brittain introduced the internal pilot study design that allows recalculation of the sample size during an ongoing trial using the estimated variance obtained from an interim analysis. However, this procedure requires the unblinding of the treatment code. Since unblinding of an ongoing trial should be avoided whenever possible, there should be some benefit of this design compared with blinded sample size recalculation procedures to justify the unveiling of the treatment code. In this paper, we compare several sample size recalculation procedures with and without unblinding. The simulation results indicate that the procedures behave similarly. In particular, breaking of the blind is not required for an efficient sample size adjustment. We also compare these pure sample size adaptation procedures with study designs which additionally allow for early stopping. Evaluation of the cumulative distribution function of the resulting sample sizes shows that the option for early stopping may lead to lower expectation but generally to a higher variability. The procedures are illustrated by an example of a trial in the treatment of depression. Copyright © 2001 John Wiley & Sons, Ltd.Keywords
This publication has 28 references indexed in Scilit:
- Efficacy and Tolerability of Hypericum Extract WS 5572 versus Placebo in Mildly to Moderately Depressed Patients - A randomized double-blind multicenter clinical trial -Pharmacopsychiatry, 2001
- A group sequential t-test with updating of sample sizeBiometrika, 2000
- Internal pilot studies I: type I error rate of the naivet-testStatistics in Medicine, 1999
- On the Use of the Upper Confidence Limit for the Variance from a Pilot Sample for Sample Size DeterminationBiometrical Journal, 1996
- On the use of a pilot sample for sample size determinationStatistics in Medicine, 1995
- Biostatistical methodology in clinical trials in applications for marketing authorizations for medicinal products. CPMP working party on efficacy of medicinal products note for guidance III/3630/92‐ENStatistics in Medicine, 1995
- Internal pilot studies for estimating sample sizeStatistics in Medicine, 1994
- Selective serotonin reuptake inhibitors: meta-analysis of efficacy and acceptability.BMJ, 1993
- Sample size re-estimation without unblinding for normally distributed outcomes with unknown varianceCommunications in Statistics - Theory and Methods, 1992
- The role of internal pilot studies in increasing the efficiency of clinical trialsStatistics in Medicine, 1990