Proton density fat fraction MRI of vertebral bone marrow: Accuracy, repeatability, and reproducibility among readers, field strengths, and imaging platforms
- 13 April 2019
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 50 (6) , 1762-1772
Abstract
Background: Chemical shift‐encoding based water‐fat MRI is an emerging method to noninvasively assess proton density fat fraction (PDFF), a promising quantitative imaging biomarker for estimating tissue fat concentration. However, in vivo validation of PDFF is still lacking for bone marrow applications.Purpose: To determine the accuracy and precision of MRI‐determined vertebral bone marrow PDFF among different readers and across different field strengths and imager manufacturers.Study Type: Repeatability/reproducibility.Subjects: Twenty‐four adult volunteers underwent lumbar spine MRI with one 1.5T and two different 3.0T MR scanners from two vendors on the same day.Field Strength/Sequence: 1.5T and 3.0T/3D spoiled‐gradient echo multipoint Dixon sequences.Assessment: Two independent readers measured intravertebral PDFF for the three most central slices of the L1–5 vertebral bodies. Single‐voxel MR spectroscopy (MRS)‐determined PDFF served as the reference standard for PDFF estimation.Statistical Tests: Accuracy and bias were assessed by Pearson correlation, linear regression analysis, and Bland–Altman plots. Repeatability and reproducibility were evaluated by Wilcoxon signed rank test, Friedman test, and coefficients of variation. Intraclass correlation coefficients were used to validate intra‐ and interreader as well as intraimager agreements.Results: MRI‐based PDFF estimates of lumbar bone marrow were highly correlated (r2 = 0.899) and accurate (mean bias, –0.6%) against the MRS‐determined PDFF reference standard. PDFF showed high linearity (r2 = 0.972–0.978) and small mean bias (0.6–1.5%) with 95% limits of agreement within ±3.4% across field strengths, imaging platforms, and readers. Repeatability and reproducibility of PDFF were high, with the mean overall coefficient of variation being 0.86% and 2.77%, respectively. The overall intraclass correlation coefficient was 0.986 as a measure for an excellent interreader agreement.Data Conclusion: MRI‐based quantification of vertebral bone marrow PDFF is highly accurate, repeatable, and reproducible among readers, field strengths, and MRI platforms, indicating its robustness as a quantitative imaging biomarker for multicentric studies.Level of Evidence: 3Technical Efficacy: Stage 2J. Magn. Reson. Imaging 2019;50:1762–1772.Keywords
This publication has 34 references indexed in Scilit:
- Proton density fat fraction (PDFF) MR imaging for differentiation of acute benign and neoplastic compression fractures of the spineEuropean Radiology, 2018
- Proton density fat fraction (PDFF) MRI for differentiation of benign and malignant vertebral lesionsEuropean Radiology, 2018
- Clinical implications of bone marrow adiposityJournal of Internal Medicine, 2017
- Whole-body MRI quantitative biomarkers are associated significantly with treatment response in patients with newly diagnosed symptomatic multiple myeloma following bortezomib inductionEuropean Radiology, 2017
- Measurement of fat content in vertebral marrow using a modified dixon sequence to differentiate benign from malignant processesJournal of Magnetic Resonance Imaging, 2016
- Spinal multiparametric MRI and DEXA changes over time in men with prostate cancer treated with androgen deprivation therapy: a potential imaging biomarker of treatment toxicityEuropean Radiology, 2016
- Comparison between modified Dixon MRI techniques, MR spectroscopic relaxometry, and different histologic quantification methods in the assessment of hepatic steatosisEuropean Radiology, 2015
- The bone–fat interface: basic and clinical implications of marrow adiposityThe Lancet Diabetes & Endocrinology, 2015
- Water–fat MRI for assessing changes in bone marrow composition due to radiation and chemotherapy in gynecologic cancer patientsJournal of Magnetic Resonance Imaging, 2013
- Quantification of Liver Fat with Magnetic Resonance ImagingMagnetic Resonance Imaging Clinics of North America, 2010