Changes in Internal Carotid Artery Doppler Velocity Measurements With Different Angles of Insonation
- 4 December 2020
- journal article
- research article
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 40 (9) , 1937-1948
Abstract
Objectives: Doppler velocity measurements are fundamental diagnostic criteria for vascular ultrasound examinations. Insonation angles are kept to 60° or less to minimize error. The purpose of this study was to assess variance of Doppler‐detected peak systolic velocity (PSV) measurements in the internal carotid arteries at different angles (45°, 50°, 55°, and 60°) with different beam steering.Methods: The PSV was recorded from the right and left internal carotid arteries in 22 asymptomatic volunteers with straight vessels (total of 44 vessels). A standardized approach was used for recording velocities with the Doppler cursor center steered and steered 15° from right to left. An analysis of variance was performed.Results: The PSV varied significantly with the 4 different angles of insonation (P < .01). The maximum variation between 45° and 60° angles within a single vessel was 29 cm/s. The average variation over the 4 angles was 14 ± 6 cm/s. Relative to the calculated mean velocity for all patients, the standard deviation for the PSV at 60° was nearly twice that recorded at 50° (7.9 versus 3.9). The best correlation of the calculated mean velocity for all patients existed between the angles of 45° and 50° [r(36) = 0.92; P < .001 for center‐steered data; and r(40) = 0.96; P < .001 for right‐steered data].Conclusions: These results indicate a statistically significant difference in the PSV measurements taken at varying Doppler angles. The greatest mean, variance, and lowest correlations all result when using 60°. The findings support the need for consistent ultrasound techniques and suggest that further study is warranted regarding the optimal Doppler angle for velocity measurements.Keywords
This publication has 7 references indexed in Scilit:
- Is a Constant Doppler Angle of Insonation Worthwhile during Carotid Duplex Ultrasound?Journal for Vascular Ultrasound, 2013
- Standardized ultrasound evaluation of carotid stenosis for clinical trials: University of Washington Ultrasound Reading CenterCardiovascular Ultrasound, 2010
- Effect of Doppler Angle in Diagnosis of Internal Carotid Artery StenosisJournal of Ultrasound in Medicine, 2006
- Carotid Artery Stenosis: Gray-Scale and Doppler US Diagnosis—Society of Radiologists in Ultrasound Consensus ConferenceRadiology, 2003
- Testing ultrasonic pulsed Doppler instruments with a physiologic string phantom.Journal of Ultrasound in Medicine, 1990
- Carotid duplex sonography: a multicenter recommendation for standardized imaging and Doppler criteria.RadioGraphics, 1988
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986