Analysis of EC-GMR data for detection of cracks under fasteners (CUFs)
- 29 December 2016
- journal article
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 52 (1-2) , 415-423
Abstract
EC-GMR measurements have been applied for detection of sub-surface corrosion and cracks under fastener (CUF) head. Generally, fastener signal amplitude is larger than the amplitude of the crack signal indication, rendering crack detection a challengiKeywords
This publication has 7 references indexed in Scilit:
- A robust multi-frequency mixing algorithm for suppression of rivet signal in GMR inspection of riveted structuresAIP Conference Proceedings, 2016
- Rotating Field EC-GMR Sensor for Crack Detection at Fastener Site in Layered StructuresIEEE Sensors Journal, 2014
- Sensor-tilt invariance analysis for eddy current signalsNDT & E International, 2012
- 3D EC-GMR sensor system for detection of subsurface defects at steel fastener sitesNDT & E International, 2012
- Multi-frequency Eddy Current Testing using a GMR based instrumentInternational Journal of Applied Electromagnetics and Mechanics, 2012
- Reduced Magnetic Vector Potential Formulation in the Finite Element Analysis of Eddy Current Nondestructive TestingIEEE Transactions on Magnetics, 2009
- Robust Face Recognition via Sparse RepresentationIEEE Transactions on Pattern Analysis and Machine Intelligence, 2008