Supplement to the 2004 update of the AAPM Task Group No. 43 Report
Open Access
- 24 May 2007
- journal article
- practice guideline
- Published by Wiley in Medical Physics
- Vol. 34 (6Part1) , 2187-2205
Abstract
Since publication of the 2004 update to the American Association of Physicists in Medicine (AAPM) Task Group No. 43 Report (TG‐43U1), several new low‐energy photon‐emitting brachytherapy sources have become available. Many of these sources have satisfied the AAPM prerequisites for routine clinical use as of January 10, 2005, and are posted on the Joint AAPM/RPC Brachytherapy Seed Registry. Consequently, the AAPM has prepared this supplement to the 2004 AAPM TG‐43 update. This paper presents the AAPM‐approved consensus datasets for these sources, and includes the following sources: Amersham model 6733, Draximage model LS‐1, Implant Sciences model 3500, IBt model 1251L, IsoAid model IAI‐125A, Mentor model SL‐125/SH‐125, and SourceTech Medical model STM1251. The Best Medical model 2335 source is also included. While the methodology used to determine these data sets is identical to that published in the AAPM TG‐43U1 report, additional information and discussion are presented here on some questions that arose since the publication of the TG‐43U1 report. Specifically, details of interpolation and extrapolation methods are described further, new methodologies are recommended, and example calculations are provided. Despite these changes, additions, and clarifications, the overall methodology, the procedures for developing consensus data sets, and the dose calculation formalism largely remain the same as in the TG‐43U1 report. Thus, the AAPM recommends that the consensus data sets and resultant source‐specific dose‐rate distributions included in this supplement be adopted by all end users for clinical treatment planning of low‐energy photon‐emitting brachytherapy sources. Adoption of these recommendations may result in changes to patient dose calculations, and these changes should be carefully evaluated and reviewed with the radiation oncologist prior to implementation of the current protocol.Keywords
This publication has 54 references indexed in Scilit:
- Improved radial dose function estimation using current version MCNP Monte-Carlo simulation: Model 6711 and ISC3500 125I brachytherapy sourcesApplied Radiation and Isotopes, 2004
- Monte Carlo dose parameters of the BrachySeed model LS-1 125I brachytherapy sourceApplied Radiation and Isotopes, 2002
- Measured transverse-axis dosimetric parameters of the model STM1251 I125 interstitial sourceJournal of Applied Clinical Medical Physics, 2002
- Dosimetric parameters of three new solid core I‐125 brachytherapy sourcesJournal of Applied Clinical Medical Physics, 2002
- Dosimetric properties of the new 125I BrachySeed™ model LS-1 sourceMedical Physics, 2002
- Measurements of the dosimetric constants for a new 103Pd brachytherapy sourceBrachytherapy, 2002
- A Monte Carlo evaluation of the dosimetric characteristics of the EchoSeed™ Model 6733 125I brachytherapy sourceBrachytherapy, 2002
- Dosimetric characteristics of the Best®double-wall 103Pd brachytherapy sourceMedical Physics, 2001
- Dosimetric study of the new InterSource125iodine seedMedical Physics, 2001
- Dosimetric characterization of a newly designed encapsulated interstitial brachytherapy source of iodine-125—model LS-1 BrachyseedTMApplied Radiation and Isotopes, 2001