Mini-augmented glenoid baseplate and mini-humeral tray reverse total shoulder arthroplasty implant comparisons: two-year clinical outcomes
Authors:
- 29 October 2023
- journal article
- research article
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 34 (2) , 1045-1056
Abstract
Background Augmented glenoid baseplate and offset humeral tray reverse total shoulder arthroplasty (RTSA) implants may decrease the mechanical impingement that creates scapular notching and improve shoulder function. This study evaluated the clinical efficacy of three different RTSA glenoid baseplate and offset humeral tray combinations for patient-reported shoulder function, pain and instability, radiographic imaging evidence of glenoid baseplate or humeral stem subsidence and migration, bony changes associated with implant loosening, and scapular notching over the initial 2 years post-RTSA. Primary outcomes included active shoulder mobility, perceived function, pain, instability, scapular notching, and implant survival. Methods Sixty-seven patients from 6 research sites received one of three different glenoid baseplate and humeral tray combinations. Group 1 (n = 21) received a mini-augmented glenoid baseplate with a standard humeral tray; Group 2 (n = 23) received a standard glenoid baseplate and a mini-humeral tray with 3 trunnion offset options; Group 3 (n = 23) received both a mini-augmented glenoid baseplate and a mini-humeral tray with 3 trunnion offset options. Subjects underwent radiologic evaluation, completed the ASES scale, the EQ-5D-5L quality of life scale, VAS shoulder pain and instability questions, and active shoulder mobility measurements pre-operatively, and 6-weeks, 6-months, 1–2 years post-RTSA. Results Improved active shoulder mobility, quality of life, perceived function, decreased shoulder pain and instability, excellent implant survival and minimal scapular notching were observed for all groups. Group 3 had better overall active shoulder mobility than the other groups and better perceived function than Group 1. Conclusion The group that received the mini-augmented glenoid baseplate and mini-humeral tray combination had better overall active shoulder flexion, external rotation at 90° abduction, and internal rotation. This group also had better perceived shoulder function compared to the group that received a mini-augmented glenoid baseplate with a standard humeral tray.Keywords
Funding Information
- Zimmer Biomet
This publication has 46 references indexed in Scilit:
- Addressing glenoid bone deficiency and asymmetric posterior erosion in shoulder arthroplastyJournal of Shoulder and Elbow Surgery, 2013
- Glenoid Component Retroversion Is Associated with OsteolysisJournal of Bone and Joint Surgery, 2013
- The relationship between scapular notching and reverse shoulder arthroplasty prosthesis designJournal of Shoulder and Elbow Surgery, 2012
- Glenoid Bone Loss in Primary Total Shoulder Arthroplasty: Evaluation and ManagementJournal of the American Academy of Orthopaedic Surgeons, 2012
- Scapular Notching: Recognition and Strategies to Minimize Clinical ImpactClinical Orthopaedics and Related Research, 2011
- An Introduction to Propensity Score Methods for Reducing the Effects of Confounding in Observational StudiesMultivariate Behavioral Research, 2011
- Effects of Acquired Glenoid Bone Defects on Surgical Technique and Clinical Outcomes in Reverse Shoulder ArthroplastyJournal of Bone and Joint Surgery, 2010
- Scapular notching in reverse shoulder arthroplastyJournal of Shoulder and Elbow Surgery, 2008
- Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuffThe Journal of Bone and Joint Surgery. British volume, 2004
- A standardized method for the assessment of shoulder functionJournal of Shoulder and Elbow Surgery, 1994