Does Gadoterate Meglumine Cause Gadolinium Retention in the Brain of Children? A Case–Control Study
- 30 October 2019
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 51 (5) , 1471-1477
Abstract
Background: Accumulation of macrocyclic gadolinium agents in children's brains remain to be determined.Purpose: To demonstrate whether there is an intracranial macrocyclic gadolinium deposition after multiple contrast‐enhanced MRI with gadoterate meglumine in a pediatric population.Study Type: Retrospective case–control.Population: In all, 45 children (age range: 5–17 years; mean, 13.7 ± 3.4 years) for the study group and 45 healthy children (age range: 5–17 years; mean, 13.7 ± 3.4 years) for the control group.Field Strength/Sequence: T1‐ and T2‐weighted axial images on a 1.5T scanner.Assessment: Children with at least three enhanced brain MRIs and an age‐ and sex‐matched control group with an unenhanced brain MRIs were compared in terms of T1 signal intensity (SI). All patients in the study group received gadoterate meglumine intravenously (0.1 mmol/kg). SI measurements were made by drawing six regions of interest (ROIs): dentate nuclei (DN), pons, globus pallidi (GP), frontal white matter (FWM), thalamus (T), clivus, and cerebrospinal fluid (CSF) for both groups on unenhanced T1‐weighted images.Statistical Tests: Student's t‐test was used for comparison of SI. The Pearson correlation was calculated for the correlation between the SI and the number of gadolinium administrations.Results: A significant difference was detected between two groups for DN/CSF, pons/CSF, GP/CSF, thalamus/CSF, and FWM/CSF (P < 0.001, P < 0.001, P = 0.002, P = 0.002, P = 0.024, respectively). There was no significant difference between the two groups for clivus/CSF (P = 0.15). A good correlation between the number of gadoterate meglumine administrations and the SI for DN/CSF, pons/CSF, GP/CSF, and T/CSF (r = 0.80, r = 0.73, r = 0.91, and r = 0.90, respectively) was found.Data Conclusion: A significant T1 SI increase reflecting gadolinium retention in the brain was detected for children with at least three gadoterate meglumine administrations in this series. The number of administrations correlated well with the increased SI.Level of Evidence: 3Technical Efficacy Stage: 5J. Magn. Reson. Imaging 2020;51:1471–1477.Keywords
This publication has 31 references indexed in Scilit:
- Intraindividual Analysis of Signal Intensity Changes in the Dentate Nucleus After Consecutive Serial Applications of Linear and Macrocyclic Gadolinium-Based Contrast AgentsInvestigative Radiology, 2016
- Pediatric Patients Demonstrate Progressive T1-Weighted Hyperintensity in the Dentate Nucleus following Multiple Doses of Gadolinium-Based Contrast AgentAmerican Journal of Neuroradiology, 2016
- Macrocyclic and Other Non–Group 1 Gadolinium Contrast Agents Deposit Low Levels of Gadolinium in Brain and Bone TissueInvestigative Radiology, 2016
- Signal Change in the Dentate Nucleus on T1-Weighted MR Images After Multiple Administrations of Gadopentetate Dimeglumine Versus GadobutrolAmerican Journal of Roentgenology, 2016
- High-Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted ImagesInvestigative Radiology, 2015
- Increasing signal intensity within the dentate nucleus and globus pallidus on unenhanced T1W magnetic resonance images in patients with relapsing-remitting multiple sclerosis: correlation with cumulative dose of a macrocyclic gadolinium-based contrast agent, gadobutrolEuropean Radiology, 2015
- Gadolinium Retention in the Dentate Nucleus and Globus Pallidus Is Dependent on the Class of Contrast AgentRadiology, 2015
- Intracranial Gadolinium Deposition after Contrast-enhanced MR ImagingRadiology, 2015
- High Signal Intensity in Dentate Nucleus on Unenhanced T1-weighted MR Images: Association with Linear versus Macrocyclic Gadolinium Chelate AdministrationRadiology, 2015
- High Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-weighted MR Images: Relationship with Increasing Cumulative Dose of a Gadolinium-based Contrast MaterialRadiology, 2014