Immunodiagnostic efficacy of detection of Schistosoma japonicum human infections in China: a meta analysis
Authors:
- Wei WangWWWei Wang
- Youzi LiYLYouzi Li
- Hongjun LiHLHongjun Li
- Yuntian XingYXYuntian Xing
- Guoli QuGQGuoli Qu
- Jianrong DaiJDJianrong Dai
- Yousheng LiangYLYousheng Liang
Open Access
- 1 January 2012
- journal article
- research article
- Published by Medknow in Asian Pacific Journal of Tropical Medicine
- Vol. 5 (1) , 15-23
Abstract
To assess the diagnostic efficacy of the currently most widely used indirect hemagglutination assay (IHA) and enzyme-linked immunosorbent assay (ELISA) for detection of Schistosoma japonicum human infections. A comprehensive search was undertaken from China National Knowledge Infrastructure, Wanfang Database, VIP Database, PubMed, Cochrane Library, Science Citation Index Expanded, Proquest, and the inclusion and exclusion criteria were strictly settled. The funnel plot was used to assess the publication bias, Cochran's Q test was employed to measure the homogeneity between studies, a summary receiver operating characteristic (SROC) curve was used to compare the diagnostic accuracy between the IHA and ELISA qualitatively by means of the Weighted Least Square method, the Ordinary Least Square method and the Robust regression method, and the diagnostic odds ratio (DOR) was drawn to compare the accuracy quantitatively. Out of 785 publications, 19 papers were eventually selected for analysis. Literature quality assessment indicated that minor publication bias existed in studies pertaining IHA test, but no bias was found in literatures regarding ELISA test. The heterogeneity test showed a heterogeneity between studies was present (χ(2)=466.07 and 34.67, both P values<0.0001). The areas under the SROC curves of IHA were all higher than that of ELISA test using the three methods (Weighted Least Square method: 0.766 vs. 0.695, Ordinary Least Square method: 0.826 vs. 0.741, Robust regression: 0.815 vs. 0.715). The TPR* values for IHA and ELISA were 0.710, 0.759, 0.749, and 0.650, 0.686 and 0.666, respectively, and OR values were 5.997, 9.937, 8.893, and 3.432, 4.784 and 3.959, respectively. The DOR of IHA was 9.41 (95% CI: 4.88-18.18), and 4.78 (95% CI: 3.21-7.13) for ELISA. All above results revealed that the diagnostic performance of IHA is better than that of ELISA. However, taking into account their unsatisfactory diagnostic value in areas with low infection intensity, a search for a better diagnostic test that can be applied in field situations in China should be given high priority.Keywords
This publication has 33 references indexed in Scilit:
- Schistosomiasis Japonica2010
- Schistosomiasis control: experiences and lessons from ChinaThe Lancet, 2008
- Schistosomiasis and water resources development: systematic review, meta-analysis, and estimates of people at riskThe Lancet Infectious Diseases, 2006
- An economic evaluation of the national schistosomiasis control programme in China from 1992 to 2000Acta Tropica, 2005
- Conquering schistosomiasis in China: the long marchActa Tropica, 2005
- Surveillance for schistosomiasis japonica in China from 2000 to 2003Acta Tropica, 2005
- The public health significance and control of schistosomiasis in China—then and nowActa Tropica, 2005
- Control of schistosomiasis in ChinaActa Tropica, 2005
- Achievements of schistosomiasis control in ChinaMemórias do Instituto Oswaldo Cruz, 2002
- Morbidity control of schistosomiasis in ChinaActa Tropica, 2002