Cleaning the dose falloff with low modulation in SBRT lung plans
- 4 May 2023
- journal article
- research article
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 9 (4) , 045002
Abstract
Purpose. This dosimetric study is intended to lower the modulation factor in lung SBRT plans generated in the Eclipse TPS that could replace highly modulated plans that are prone to the interplay effect. Materials and methods. Twenty clinical lung SBRT plans with high modulation factors (≥4) were replanned in Varian Eclipse TPS version 15.5 utilizing 2 mm craniocaudal and 1 mm axial block margins followed by light optimization in order to reduce modulation. A unique plan optimization methodology, which utilizes a novel shell structure (OptiForR50) for R50% optimization in addition to five consecutive concentric 5 mm shells, was utilized to control dose falloff according to RTOG 0813 and 0915 recommendations. The prescription varied from 34–54 Gy in 1–4 fractions, and the dose objectives were PTV D95% = Rx, PTV Dmax < 140% of Rx, and minimizing the modulation factor. Plan evaluation metrics included modulation factor, CIRTOG, homogeneity index (HI), R50%, D2cm, V105%, and lung V8–12.8Gy (Timmerman Constraint). A random-intercept linear mixed effects model was used with a p ≤ 0.05 threshold to test for statistical significance. Results. The retrospectively generated plans had significantly lower modulation factors (3.65 ± 0.35 versus 4.59 ± 0.54; p < 0.001), lower CIRTOG (0.97 ± 0.02 versus 1.02 ± 0.06; p = 0.001), higher HI (1.35 ± 0.06 versus 1.14 ± 0.04; p < 0.001), lower R50% (4.09 ± 0.45 versus 4.56 ± 0.56; p < 0.001), and lower lungs V8–12.8Gy (Timmerman) (4.61% ± 3.18% versus 4.92% ± 3.37%; p < 0.001). The high dose spillage V105% was borderline significantly lower (0.44% ± 0.49% versus 1.10% ± 1.64%; p = 0.051). The D2cm was not statistically different (46.06% ± 4.01% versus 46.19% ± 2.80%; p = 0.835). Conclusion. Lung SBRT plans with significantly lower modulation factors can be generated that meet the RTOG constraints, using our planning strategy.Keywords
This publication has 31 references indexed in Scilit:
- A Randomized Phase 2 Study Comparing 2 Stereotactic Body Radiation Therapy Schedules for Medically Inoperable Patients With Stage I Peripheral Non-Small Cell Lung Cancer: NRG Oncology RTOG 0915 (NCCTG N0927)International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2015
- Interplay Effect During Lung SBRT With VMAT Delivered by Flattening Filter–Free BeamsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2014
- Impact of plan parameters on the dosimetric accuracy of volumetric modulated arc therapyMedical Physics, 2013
- Consideration of optimal isodose surface selection for target coverage in micro-multileaf collimator-based stereotactic radiotherapy for large cystic brain metastases: comparison of 90%, 80% and 70% isodose surface-based planningBritish Journal of Radiology, 2012
- A novel modified dynamic conformal arc technique for treatment of peripheral lung tumors using stereotactic body radiation therapyPractical Radiation Oncology, 2011
- Experience of micromultileaf collimator linear accelerator based single fraction stereotactic radiosurgery: Tumor dose inhomogeneity, conformity, and dose fall offMedical Physics, 2011
- Dose Gradient Analyses in Linac-based Intracranial Stereotactic Radiosurgery Using Paddick's Gradient Index: Consideration of the Optimal Method for Plan EvaluationJournal of Radiation Research, 2011
- Feasibility of Single-Isocenter Volumetric Modulated Arc Radiosurgery for Treatment of Multiple Brain MetastasesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- A simple dose gradient measurement tool to complement the conformity indexJournal of Neurosurgery, 2006
- Effects of motion on the total dose distributionSeminars in Radiation Oncology, 2004