The influence of the solar radiation heat input into the room on the level of energy-efficient thermal protection of the building
Authors:
Open Access
- 29 May 2019
- conference paper
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 97, 03022
Abstract
The task of increasing the energy efficiency of external enclosing structures is often considered as the need to increase their heat transfer resistance. At the same time, the main indicator of this efficiency is the heat consumption reduction for heating of the buildings having high thermal protection. Despite the fact that Russia is a rather cold country with a long heating period in most of its territory, the lack of accounting the cold consumption in warm period of the year leads to wrong understanding by the specialists of the energy expediency of the building thermal protection level. In today’s world, more and more buildings, which have been built, house the civil technologies with high heat emissions, i.e. administrative and office, entertainment, training, shopping and other buildings. These buildings require high energy consumption for cooling, which is often necessary even during the heating period. Taking into account the heat input from the solar radiation with variable intensity throughout the year, the thermal protection level is subject to significant corrections. This is due to the fact that often the cooling of the room is required during the periods when the outdoor temperature is below the maximum allowable room temperature. During these periods, the enhanced thermal protection is an obstacle to the natural heat outflow from the premises. The calculations showed that the higher is the solar radiation heat input, the smaller is the part of energetically feasible buildings according to the basic norms prescribed by the SP 50.13330.2012. And although the sanitary and hygienic requirements show no reasons of the building heat insulation from the energy point of view, the conclusions about the profitability of the building insulation with a reduced basic resistance to heat transfer of walls and coatings of the building are economically significant.Keywords
This publication has 7 references indexed in Scilit:
- Modelling of double skin facades in whole-building energy simulation tools: A review of current practices and possibilities for future developmentsBuilding Simulation, 2019
- Thermal behavior and energy saving analysis of a flat with different energy efficiency measures in six climatesBuilding Simulation, 2018
- Thermal performance investigation of a PCM-enhanced wall/roof in northern MoroccoBuilding Simulation, 2018
- Choice of Thermal Protection of an Office Building of the Transport Infrastructure by Economic Reasons2017
- The impact of building massing on net-zero achievability for office buildingsBuilding Simulation, 2017
- Effect of geometric factors on the energy performance of high-rise office towers in Tianjin, ChinaBuilding Simulation, 2017
- Relationship between built form and energy performance of office buildings in a severe cold Chinese regionBuilding Simulation, 2016