Purpose To determine the value of ultrasound biomicroscopy (UBM) in the assessment of ocular hypotony in cases where the underlying pathologic mechanism remains unclear after extensive clinical examination. Methods In a retrospective study, the records of 60 patients who had undergone UBM to elucidate the underlying structural abnormalities of chronic ocular hypotony (intraocular pressure of 0–8 mmHg) were evaluated. Most patients (47 of 60 eyes) had a history of intraocular surgery or of other ocular diseases (e.g., uveitis), and after careful clinical examination, the cause had remained unclear. All patients were observed up for a minimum of 12 months. Results The associated pathoanatomy of the hypotony was demonstrated by UBM in 95% of the cases. Ciliary body abnormalities were present in 80% of the eyes. Therapeutic intervention was associated with restoration of normal ocular pressure in 50% of the cases. Often more than one intervention was necessary. A long duration of hypotony did not impede reaching the therapeutic goal of normalizing intraocular pressure and preventing phthisis. Conclusions Ultrasound biomicroscopy is a new tool for detecting the underlying structural abnormalities in ocular hypotony. In cases where clinical examination is not sufficient it can be of great help in deciding on a course of treatment.Keywords
This publication has 20 references indexed in Scilit:
- Ultrasound Biomicroscopic Findings in a Case of CyclodialysisOphthalmologica, 1998
- THE ARTIFICIAL IRIS DIAPHRAGM FOR VITREORETINAL SILICONE OIL SURGERYRetina, 1997
- Ultrasound Biomicroscopy in the Diagnosis of Persistent Hypotony After VitrectomyAmerican Journal of Ophthalmology, 1997
- Pathogenetic Mechanisms in Anterior Proliferative VitreoretinopathyAmerican Journal of Ophthalmology, 1992
- Clinical Use of Ultrasound BiomicroscopyOphthalmology, 1991
- Subsurface Ultrasound Microscopic Imaging of the Intact EyeOphthalmology, 1990
- Inflow and outflow relations after intraocular fluid ? Healon exchange in a case of chronic ocular hypotensionInternational Ophthalmology, 1985
- Treatment of Hypotony Following Filtering Surgery for GlaucomaAmerican Journal of Ophthalmology, 1971
- Management of Persistent Hypotony After Planned or Inadvertent CyclodialysisAmerican Journal of Ophthalmology, 1971
- A Major Cause of HypotonyAmerican Journal of Ophthalmology, 1961