Femoral Rollback After Cruciate-Retaining and Stabilizing Total Knee Arthroplasty
Authors:
- 1 May 2003
- journal article
- section i-symposium
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 410 (410) , 101-113
Abstract
Limited data comparing the kinematics of posterior cruciate ligament-retaining or substituting total knee arthroplasty with its own intact knee under identical loadings is available. In the current study, posterior femoral translation of the lateral and medial femoral condyles under unloaded conditions was examined for intact, cruciate-retaining, cruciate ligament-deficient cruciate-retaining and posterior-substituting knee arthroplasties. Cruciate-retaining and substituting total knee arthroplasties behaved similarly to the cruciate-deficient cruciate-retaining total knee arthroplasty between 0° and 30° flexion. Beyond 30°, the posterior cruciate-retaining arthroplasty showed a significant increase in posterior translation of both femoral condyles. The posterior cruciate-substituting arthroplasty only showed a significant increase in posterior femoral translation after 90°. At 120°, both arthroplasties restored approximately 80% of that of the native knee. Posterior translation of the lateral femoral condyle was greater than that observed in the medial condyle for all knees, indicating the presence of internal tibial rotation during knee flexion. The data showed that the posterior cruciate ligament is an important structure in posterior cruciate-retaining total knee arthroplasty and proper balancing is imperative to the success of the implant. The cam-spine engagement is valuable in restoring posterior femoral translation in posterior cruciate-substituting total knee arthroplasty.Keywords
This publication has 29 references indexed in Scilit:
- Clinical outcome of arthroscopic repair of the posterior cruciate ligamentDer Unfallchirurg, 1999
- A comparison of isokinetic strength testing and gait analysis in patients with posterior cruciate-retaining and substituting knee arthroplastiesThe Journal of Arthroplasty, 1998
- A Point Cluster Method for In Vivo Motion Analysis: Applied to a Study of Knee KinematicsJournal of Biomechanical Engineering, 1998
- In Vivo Anteroposterior Femorotibial Translation of Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1998
- Range of motion after total knee arthroplasty The effect of implant design and weight-bearing conditionsThe Journal of Arthroplasty, 1998
- Kinematics of the knee joint in deep flexion: a radiographic assessmentMedical Engineering & Physics, 1998
- In vivo kinematics of cruciate-retaining and -substituting knee arthroplastiesThe Journal of Arthroplasty, 1997
- In Vivo Knee Kinematics Derived Using an Inverse Perspective TechniqueClinical Orthopaedics and Related Research, 1996
- Tradeoffs between motion and stability in posterior substituting knee arthroplasty designJournal of Biomechanics, 1995
- Retention of the posterior cruciate in total knee arthroplastyThe Journal of Arthroplasty, 1988