Arterial Pressure-Flow Relationship in Patients Undergoing Cardiopulmonary Bypass
Authors:
- Jorge UrzuaJUJorge Urzua
- Gladys MenesesGMGladys Meneses
- Christian FajardoCFChristian Fajardo
- Guillermo LemaGLGuillermo Lema
- Roberto CanessaRCRoberto Canessa
- Carla M. SaccoCSCarla M. Sacco
- Jessica MedelJMJessica Medel
- Maria Eugenia VergaraMVMaria Eugenia Vergara
- Manuel IrarrazavalMIManuel Irarrazaval
- Sergio MoranSMSergio Moran
- 1 May 1997
- journal article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 84 (5) , 958-963
Abstract
Were used. During stable bypass, mean arterial pressure was recorded first with blood flow 2.2 L [centered dot] min (-1) [centered dot] m-2. Flow was then increased to 2.9 L [centered dot] min (-1) [centered dot] m-2 for 10 s and reverted to baseline for 1 min. Then it was decreased to 1.45 L [centered dot] min-1 [centered dot] m-2 for 10 s, and reverted to baseline for 1 min. Subsequently, it was decreased to 0.73 L [centered dot] min-1 [centered dot] m-2 for 10 s and then reverted to baseline. Similar sets of measurements were repeated after 0.25 mg of phenylephrine and once the patient was rewarmed. The pressure-flow function was individually determined by regression, and the critical pressure estimated by extrapolation to zero flow. All patients had zero-flow critical pressure during hypothermia, with a mean value of 21.8 +/- 6.4 mm Hg (range 8.8-38.9). It increased after 0.25 mg phenylephrine to 25.4 +/- 7.2 mm Hg (range 12.2-43.9, P < 0.001). During normothermia, critical pressure was 21.2 +/- 5 mm Hg (range 13.4-30.9), not significantly different from hypothermia. During hypothermia, the slope of the pressure-flow function (i.e., resistance) was 14.9 +/- 3.5 mm Hg [centered dot] L-1 [centered dot] min-1 [centered dot] m-2 (range 7.6-22.1). It increased significantly (P < 0.001) after phenylephrine, to 19.7 +/- 6.2 mm Hg [centered dot] L-1 [centered dot] min-1 [centered dot] m-2 (range 11.4-40.5), and returned to 15.4 +/- 3.4 mm Hg [centered dot] L-1 [centered dot] min-1 [centered dot] m-2 (range 10.1-24.2) during normothermic bypass. Systemic vascular resistance appeared to vary reciprocally with blood flow, although this finding may represent a mathematical artifact, which can be avoided by using zero-flow critical pressure in the vascular resistance equation. (Anesth Analg 1997;84:958-63)...Keywords
This publication has 13 references indexed in Scilit:
- Mechanism of Systemic Vasodilation During Normovolemic HemodilutionAnesthesia & Analgesia, 1995
- Effects of arterial and venous pressure alterations on transcapillary fluid exchange during raised tissue pressureIntensive Care Medicine, 1994
- Determination of the deformation potentials of GaAs0.80P0.20Journal of Applied Physics, 1994
- Thermoregulatory vasoconstriction increases the difference between femoral and radial arterial pressuresJournal of Clinical Monitoring and Computing, 1994
- Pressure-flow relationships of the pulmonary circulation during endotoxin infusion in intact dogsCritical Care Medicine, 1992
- Is there a systemic waterfall in humans? Evidence from haemodynamic measurements during artificial circulatory arrestJournal of Cardiothoracic and Vascular Anesthesia, 1992
- Effects of blood flow on lung ACE kinetics: evidence for microvascular recruitmentJournal of Applied Physiology, 1991
- Starling resistor versus compliance. Which explains the zero-flow pressure of a dynamic arterial pressure-flow relation?Circulation Research, 1990
- Changes in hemodynamic variables during hypothermic cardiopulmonary bypassThe Journal of Thoracic and Cardiovascular Surgery, 1990
- Hemodynamics of collapsible vessels with tone: the vascular waterfallJournal of Applied Physiology, 1963