Numerical and in vivo validation of fast cine displacement‐encoded with stimulated echoes (DENSE) MRI for quantification of regional cardiac function
Open Access
- 7 July 2009
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 62 (3) , 682-690
Abstract
Quantitative assessment of regional cardiac function can improve the accuracy of detecting wall motion abnormalities due to heart disease. While recently developed fast cine displacement‐encoded with stimulated echoes (DENSE) MRI is a promising modality for the quantification of regional myocardial function, it has not been validated for clinical applications. The purpose of this study, therefore, was to validate the accuracy of fast cine DENSE MRI with numerical simulation and in vivo experiments. A numerical phantom was generated to model physiologically relevant deformation of the heart, and the accuracy of fast cine DENSE was evaluated against the numerical reference. For in vivo validation, 12 controls and 13 heart‐disease patients were imaged using both fast cine DENSE and myocardial tagged MRI. Numerical simulation demonstrated that the echo‐combination DENSE reconstruction method is relatively insensitive to clinically relevant resonance frequency offsets. The strain measurements by fast cine DENSE and the numerical reference were strongly correlated and in excellent agreement (mean difference = 0.00; 95% limits of agreement were 0.01 and −0.02). The strain measurements by fast cine DENSE and myocardial tagged MRI were strongly correlated (correlation coefficient = 0.92) and in good agreement (mean difference = 0.01; 95% limits of agreement were 0.07 and −0.04). Magn Reson Med, 2009.Keywords
This publication has 36 references indexed in Scilit:
- Direct three-dimensional myocardial strain tensor quantification and tracking using zHARPMedical Image Analysis, 2008
- Adaptive Postprocessing Techniques for Myocardial Tissue Tracking with Displacement-encoded MR ImagingRadiology, 2008
- Improved cine displacement‐encoded MRI using balanced steady‐state free precession and time‐adaptive sensitivity encoding parallel imaging at 3 TNMR in Biomedicine, 2007
- Detailed analysis of myocardial motion in volunteers and patients using high‐temporal‐resolution MR tissue phase mappingJournal of Magnetic Resonance Imaging, 2006
- Increasing the signal‐to‐noise ratio in DENSE MRI by combining displacement‐encoded echoesMagnetic Resonance in Medicine, 2004
- Cardiac SSFP imaging at 3 TeslaMagnetic Resonance in Medicine, 2004
- Standardized Myocardial Segmentation and Nomenclature for Tomographic Imaging of the HeartCirculation, 2002
- Reducing flow artifacts in echo-planar imagingMagnetic Resonance in Medicine, 1997
- Magnetic resonance imaging of myocardial kinematics. technique to detect, localize, and quantify the strain rates of the active human myocardiumMagnetic Resonance in Medicine, 1992
- Direct Cardiac NMR Imaging of Heart Wall and Blood Flow VelocityJournal of Computer Assisted Tomography, 1984