Water Quality Study on the Hot and Cold Water Supply Systems at Vietnamese Hotels
Open Access
Abstract
This study was conducted as part of the Joint Crediting Mechanism (JCM) of the Japanese Ministry of Economy, Trade and Industry, and the Ministry of the Environment project’s preparation in Vietnam. Samples were taken from hot and cold water supplies from guest rooms’ faucets in 12 hotels in Hanoi city, Vietnam, and 13 hotels in Japan for comparison. A simple water quality measurement and determination of Legionella was carried out. The results showed that residual effective chlorine—which guarantees bactericidal properties—was not detected in tap water supplied in hotel rooms in Vietnam, and nitrite (an indicator of water pollution) was detected in 40% of buildings. In the hotels in Japan, the prescribed residual chlorine concentration met the prescribed levels, and nitrite was not detected. Additionally, while there was no Legionella detected in the Japanese cases, it was detected in most of the Vietnamese hotels, which were found to manage the hot water storage tank at low temperatures of 40–50 °C. It was found that there were deficiencies in cold and hot water supply quality, and that there was no effective system in place for building operation maintenance and management.Keywords
This publication has 10 references indexed in Scilit:
- Response to Comments on Whiley Legionella Risk Management and Control in Potable Water Systems: Argument for the Abolishment of Routine Testing. Int. J. Environ. Res. Public Health 2017, 14, 12International Journal of Environmental Research and Public Health, 2017
- Water Quality, Sanitation, and Hygiene Conditions in Schools and Households in Dolakha and Ramechhap Districts, Nepal: Results from A Cross-Sectional SurveyInternational Journal of Environmental Research and Public Health, 2017
- Legionella Risk Management and Control in Potable Water Systems: Argument for the Abolishment of Routine TestingInternational Journal of Environmental Research and Public Health, 2016
- Efficacy of a Low Dose of Hydrogen Peroxide (Peroxy Ag+) for Continuous Treatment of Dental Unit Water Lines: Challenge Test with Legionella pneumophila Serogroup 1 in a Simulated Dental Unit WaterlineInternational Journal of Environmental Research and Public Health, 2016
- Investigation of Legionella Contamination in Bath Water Samples by Culture, Amoebic Co-Culture, and Real-Time Quantitative PCR MethodsInternational Journal of Environmental Research and Public Health, 2015
- Occurrence and Control of Legionella in Recycled Water SystemsPathogens, 2015
- Contribution of Water Saving to a Stable Power Supply in VietnamWater, 2015
- CO2 Reduction Potential of Water Saving in VietnamWater, 2015
- The CO2 Emission Factor of Water in JapanWater, 2012
- Creation of Carbon Credits by Water SavingWater, 2012