Surgical outcomes of dual-plate fixation for periprosthetic femur fractures around a stable hip arthroplasty stem
Authors:
- 18 May 2021
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 142 (12) , 3605-3611
Abstract
Introduction The incidence of periprosthetic femur fractures is increasing. Multiple treatment methods exist to treat fractures surrounding stable hip arthroplasty implants including locking plate fixation, cable fixation, allograft augmentation, and revision arthroplasty. No consensus regarding optimal treatment has been reached, and significant complications remain. Recently, biomechanical studies have demonstrated the benefits of orthogonal dual-plate fixation, but little clinical data exist. The purpose of the current study was to investigate the clinical and radiographic outcomes of dual-plated periprosthetic femur fractures around stable hip stems. Materials and methods Patients with periprosthetic femur fractures following hip arthroplasty with a stable femoral stem treated with dual-plate fixation were identified through chart review at a single institution. Fracture classification, fixation characteristics, radiographic outcomes, clinical outcomes and complications including re-operation were recorded. Results Over a 12-year period, 31 patients (mean age 77 years at surgery, range 48–94) underwent dual plating by three traumatologists for implant-stable periprosthetic femur fractures surrounding a hip arthroplasty stem. There were 27 Vancouver B1-type and 9 inter-prosthetic fractures. Average follow-up was 2 years. Of the 26 patients with minimum 6-month follow-up, 24 (92%) united after index surgery (mean time to union 6.0 months, range 1.5–14.0). Mean time to full weight-bearing post-operatively was 2.6 months (range 1.5–4.0 months). Two patients required secondary surgery to address nonunion. Conclusions Dual-plating achieved high union rates with an acceptable complication profile for the treatment of periprosthetic femur fractures surrounding a stable hip arthroplasty stem. Our preferred fixation construct involves a lateral plate spanning the entire femur secured with non-locking bicortical screws supplemented with an anteriorly based reconstruction plate. Additional prospective research is required to confirm the results of this study.Keywords
This publication has 30 references indexed in Scilit:
- A biomechanical study on proximal plate fixation techniques in periprosthetic femur fracturesInjury, 2014
- Treatment of periprosthetic femur fractures around a well-fixed hip arthroplasty implant: span the whole boneArchives of orthopaedic and trauma surgery, 2013
- Superior outcome of strut allograft-augmented plate fixation for the treatment of periprosthetic fractures around a stable femoral stemInjury, 2013
- Periprosthetic Vancouver type B1 and C fractures treated by locking-plate osteosynthesisActa Orthopaedica, 2012
- Long-term functional outcome in geriatric hip fracture patientsArchives of orthopaedic and trauma surgery, 2011
- The Effect of Fixation Technique on the Stiffness of Comminuted Vancouver B1 Periprosthetic Femur FracturesThe Journal of Arthroplasty, 2010
- Biomechanical Evaluation of Periprosthetic Femoral Fracture FixationJournal of Bone and Joint Surgery, 2008
- Fixation of Periprosthetic Femoral Shaft Fractures Associated With Cemented Femoral StemsJournal of Orthopaedic Trauma, 2006
- Indirect Reduction and Plate Fixation, without Grafting, for Periprosthetic Femoral Shaft Fractures About a Stable Intramedullary ImplantJournal of Bone and Joint Surgery, 2005
- Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stemThe Journal of Arthroplasty, 2000