Microvascular Stress Analysis
Authors:
- Jehad Al-SukhunJAJehad Al-Sukhun
- Heikki PenttiläHPHeikki Penttilä
- Nureddin AshammakhiNANureddin Ashammakhi
- 1 May 2011
- journal article
- Published by Wolters Kluwer Health in Journal of Craniofacial Surgery
- Vol. 22 (3) , 883-887
Abstract
To develop a finite element model (FEM) to study the effect of the vascular wall compliance on blood flow at the graft/recipient vessel junction. Finite element models of the end-to-end and end-to-side anastomoses were constructed. Simulations were performed with a computer using the finite element software NISA. The FEMs were then used to study the effects of changing the elasticity of the vascular wall on its predictions. Deformations were relatively large; the maximum displacement for the compliant model, end-to-end anastomosis, was 55 and 88 mm for the 90-degree end-to-side anastomosis. The maximum displacement for the rigid model, end-to-end anastomosis, was 155 and 188 mm for the 90-degree end-to-side anastomosis. When the angle of inset was set at 45 degrees, there was no remarkable difference in deformation between the compliant and rigid models. The principal stresses were remarkably less at the graft/vessel junction in models of compliant grafts and compliant vessels than for rigid wall models. The 45-degree end-to-side anastomosis seems to be the best technique when planning microvascular anastomosis for elderly patients and/or patients with systemic disease, which reduces vascular wall elasticity.Keywords
This publication has 16 references indexed in Scilit:
- Microvascular stress analysisBritish Journal of Oral and Maxillofacial Surgery, 2007
- Hemodynamics of human carotid artery bifurcations: Computational studies with models reconstructed from magnetic resonance imaging of normal subjectsJournal of Vascular Surgery, 1998
- Compliance mismatch may promote graft–artery intimal hyperplasia by altering suture-line stressesJournal of Biomechanics, 1997
- Computational blood flow modellingJournal of Biomechanics, 1997
- Fluid wall shear stress measurements in a model of the human abdominal aorta: oscillatory behavior and relationship to atherosclerosisAtherosclerosis, 1994
- Pulsatile Velocity Measurements in a Model of the Human Abdominal Aorta Under Resting ConditionsJournal of Biomechanical Engineering, 1994
- The Effect of Wall Distensibility on Flow in a Two-Dimensional End-to-Side AnastomosisJournal of Biomechanical Engineering, 1994
- Pulsatile Velocity Measurements in a Model of the Human Abdominal Aorta Under Simulated Exercise and Postprandial ConditionsJournal of Biomechanical Engineering, 1994
- Flow pattern analysis in the abdominal aorta with velocity‐encoded cine MR imagingJournal of Magnetic Resonance Imaging, 1993
- Three-dimensional numerical analysis of pulsatile flow and wall shear stress in the carotid artery bifurcationJournal of Biomechanics, 1991