Balloon dilatation of critical stenosis of the pulmonary valve in neonates.
Authors:
- S A QureshiSQS A Qureshi
- J M ParsonsJPJ M Parsons
- S ArabSAS Arab
- E J BakerEBE J Baker
- M TynanMTM Tynan
Open Access
Abstract
Percutaneous balloon dilatation was attempted in 15 consecutive neonates (mean age 7.3 (range 1-27) days and weight 3.2 (range 2.5-4.1) kg) with critical stenosis of the pulmonary valve. Dilatation was successful in 11 (73%) patients. The mean balloon to annulus ratio was 1.1 (range 0.6-1.77). The ratio of right ventricle to femoral artery systolic pressure decreased from a mean (1 SD) of 1.4 (0.32) before to 0.8 (0.24) after dilatation and the transvalvar gradient decreased from 81 (29.7) mm Hg before to 33 (27.7) mm Hg after dilatation. All four (27%) patients in whom dilatation was unsuccessful underwent surgical valvotomy. Complications of balloon dilatation occurred in three (20%) patients; these included retroperitoneal haematoma (one) and iliofemoral venous occlusion (two). In one (7%) patient severe hypoxia and hypotension developed when the valve was crossed with a guide wire and balloon catheter. Despite successful dilatation he died 7 days after the procedure. During a mean (1 SD) follow up of 2 (1.7) years, seven (64%) of the 11 patients remained free of important restenosis. One patient required repeat dilatation three weeks after the initial procedure. In three (27%) patients restenosis developed 4-9 months after dilatation and all three had surgical valvotomy. Of the four patients initially referred for surgery three required a second operation and one required balloon dilatation. Percutaneous balloon dilatation gave effective relief of critical pulmonary stenosis in most neonates but complications and restenosis requiring surgery were common.Keywords
This publication has 23 references indexed in Scilit:
- Further observations on the effect of balloon size on the short term and intermediate term results of balloon dilatation of the pulmonary valve.Heart, 1988
- Long-term results of balloon pulmonary valvuloplasty of valvar pulmonic stenosisAmerican Heart Journal, 1988
- Percutaneous transluminal balloon pulmonary valvuloplasty for the relief of pulmonary valve stenosis with special reference to double-balloon techniqueAmerican Heart Journal, 1986
- The risk of diagnostic radiation of the newbornBritish Journal of Radiology, 1986
- Results of balloon valvuloplasty in the treatment of congenital valvar pulmonary stenosis in childrenThe American Journal of Cardiology, 1985
- Morphologic changes induced by dilation of the pulmonary valve anulus with overlarge balloons in normal newborn lambsThe American Journal of Cardiology, 1985
- Percutaneous transluminal balloon valvuloplasty for pulmonary valve stenosis.Circulation, 1984
- RELIEF OF PULMONARY VALVE STENOSIS IN FIRST WEEK OF LIFE BY PERCUTANEOUS BALLOON VALVULOPLASTYThe Lancet, 1984
- Percutaneous Balloon Valvuloplasty: A New Method for Treating Congenital Pulmonary-Valve StenosisThe New England journal of medicine, 1982
- Surgical management of life-threatening ventricular arrhythmias in patients with coronary artery disease.Circulation, 1977