16(14) microns TE CO2 laser working on the 0200(1000)-0110 and 0201(1001)-0111 bands
Authors:
- 1 September 2008
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21601518,p. 43-45
Abstract
The optimization of the active medium and its electrical discharge pumping conditions based on the original technique of gain measurements on the several bands (00 0 1-10 0 0, 00 0 2-10 0 1, 01 1 1-11 1 0) of CO 2 molecule allowed to obtain in the simple TE CO 2 laser with UV preionization (the active media length is 70 cm, the width of electrodes is 2.5 cm, the interval between electrodes is 2 cm, the voltage on the 0.2 microFarad capacitor is 6.5 kV) the powerful lasing (57 mJ) on the 02 0 0(10 0 0)-01 1 0 band (lambda~l16 (14) micrometers) at room temperature.. To increase the power performances of the 16 (14) microns CO 2 laser the possibility of lasing on the 02 0 1-01 1 1 band have been experimentally and theoretically investigated under the combined (electrical + optical) excitation of the active medium. The necessary conditions for the effective lasing have been determined. It is shown that in optimum conditions the output energy can reach 1,3 J/l at the peak power 5 MW and at the full efficiency of 2%.Keywords
This publication has 3 references indexed in Scilit:
- Transversely excited CO2lidar laser tunable over lines of regular and nontraditional bandsQuantum Electronics, 1995
- Two-color TEA CO2 laser oscillation on the lines of regular and hot bandsApplied Physics B, 1987
- Investigation of the vibrational temperature kinetics in a TEA CO2laserSoviet Journal of Quantum Electronics, 1982