Regeneration of Rotator Cuff Tear Using Electrospun Poly( d , l ‐Lactide‐Co‐Glycolide) Scaffolds in a Rabbit Model
Authors:
- 11 October 2012
- journal article
- Published by Wiley in Arthroscopy
- Vol. 28 (12) , 1790-1799
Abstract
Purpose: The purpose of this study was to evaluate an application of poly( d , l ‐lactide‐co‐glycolide) (PLG) scaffold created by electrospinning in a rabbit rotator cuff defect model. Methods: Forty‐two Japanese white rabbits were used in this study. Defects of the infraspinatus tendon were created, and the PLG scaffolds were implanted. Contralateral infraspinatus tendons were reattached without creating defects. Histologic analyses were performed 4, 8, and 16 weeks after the operation, and mechanical evaluations were performed 0, 4, 8, and 16 weeks after the operation. Results: Scaffold fibers remained without dissolution and spindle‐shaped cells were observed inside of the scaffold at 4 weeks postoperatively. At 8 weeks, the PLG scaffold had dissolved and bone formation was observed at the scaffold‐bone interface. At 16 weeks, the scaffold‐bone interface matured and expression of type II collagen was observed. A statistical difference in ultimate failure load was not seen between the scaffold group and reattachment group or normal tendon after 8 weeks postoperatively. The stiffness in the scaffold group was not significantly different from that in the reattachment group at each time point. However, it was significantly weaker than normal tendon at each time point. Conclusions: Transplantation of cell‐free PLG scaffold showed cell migration and type II collagen and proteoglycan expression at the scaffold‐bone junction by 16 weeks postoperatively with a sufficient ultimate failure load in a rabbit rotator cuff defect model. Clinical Relevance: The PLG scaffold could be applied to bridge rotator cuff defects. The results showed that bridging with scaffold can be equivalent to reattachment.Keywords
This publication has 28 references indexed in Scilit:
- Application of layered poly (L-lactic acid) cell free scaffold in a rabbit rotator cuff defect modelBMC Sports Science, Medicine and Rehabilitation, 2011
- The effect of porosity and mechanical property of a synthetic polymer scaffold on repair of osteochondral defectsInternational Orthopaedics, 2008
- Tendon-Bone Insertion Repair and Regeneration Using Polyglycolic Acid Sheet in the Rabbit Rotator Cuff Injury ModelThe American Journal of Sports Medicine, 2008
- Autologous Tenocyte Therapy Using Porcine-Derived Bioscaffolds for Massive Rotator Cuff Defect in RabbitsTissue Engineering, 2007
- Biomechanical evaluation of a rotator cuff defect model augmented with a bioresorbable scaffold in goatsJournal of Shoulder and Elbow Surgery, 2006
- Reconstruction of large rotator cuff tendon defects with porcine small intestinal submucosa in an animal modelJournal of Shoulder and Elbow Surgery, 2006
- Rotator cuff regeneration using chitin fabric as an acellular matrixJournal of Shoulder and Elbow Surgery, 2006
- Delay of supraspinatus repair by up to 12 weeks does not impair enthesis formation: A quantitative histologic study in rabbitsJournal of Orthopaedic Research, 2005
- Application of Tissue Engineering Techniques for Rotator Cuff Regeneration Using a Chitosan-Based Hyaluronan Hybrid Fiber ScaffoldThe American Journal of Sports Medicine, 2005
- Reconstruction of a defect of the rotator cuff with polytetrafluoroethylene felt graftThe Journal of Bone and Joint Surgery. British volume, 2003