Point-tracked quantitative analysis of left ventricular surface motion from 3-D image sequences
Authors:
- A.J. SinusasASA.J. Sinusas
- R.T. ConstableRCR.T. Constable
- E. RitmanERE. Ritman
- J.S. DuncanJDJ.S. Duncan
- 1 January 2000
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 19 (1) , 36-50
Abstract
Proposes and validates the hypothesis that one can use differential shape properties of the myocardial surfaces to recover dense field motion from standard three-dimensional (3-D) image sequences (MRI and CT). Quantitative measures of left ventricular regional function can be further inferred from the point correspondence maps. The noninvasive, algorithm-derived results are validated on two levels. First, the motion trajectories are compared to those of implanted imaging-opaque markers of a canine model in two imaging modalities, where subpixel accuracy is achieved. Second, the validity of using motion parameters (path length and thickness changes) for detecting myocardial injury area is tested by comparing algorithms derived results to postmortem analysis TTC staining of myocardial tissue, where the achieved Pearson product-moment correlation value is 0.968.Keywords
This publication has 46 references indexed in Scilit:
- A recursive filter for temporal analysis of cardiac motion2002
- Implementation of displacement field fitting for calculating 3D myocardial deformations from parallel-tagged MR images2002
- Constrained deformable superquadrics and nonrigid motion tracking2002
- Measurement of non-rigid motion using contour shape descriptors2002
- Motion analysis and epicardial deformation estimation from angiography data2002
- Tracking myocardial deformation using phase contrast MR velocity fields: a stochastic approachIEEE Transactions on Medical Imaging, 1996
- Computer Analysis of Heart Motion from Two-Dimensional EchocardiogramsIEEE Transactions on Biomedical Engineering, 1987
- Blood Flow Imaging by Cine Magnetic ResonanceJournal of Computer Assisted Tomography, 1986
- An Investigation of Smoothness Constraints for the Estimation of Displacement Vector Fields from Image SequencesIEEE Transactions on Pattern Analysis and Machine Intelligence, 1986
- Computing the n-dimensional Delaunay tessellation with application to Voronoi polytopesThe Computer Journal, 1981