Background and Objective. A common reconstruction procedure after a wide resection of bone tumors around the knee is endoprosthetic knee replacement. The aim of this study was to investigate the characteristics of bone injury of the patient after endoprosthetic knee replacement during walking. Methods. A subject-specific finite element model of the femur-prosthesis-tibia complex was established via CT scans. To obtain its physiologically realistic loading environments, the musculoskeletal inverse dynamic analysis was implemented. The extracted muscle forces and ground forces were then applied to the finite element model to investigate bone stress distribution at various stages of the gait cycle. Results. The maximum femur stress of each stage varied from 33.14 MPa to 70.61 MPa in the gait cycle. The stress concentration position with a distance of 267.2 mm to the tibial plateau showed a good agreement with the patient injury data. Conclusions. Overall results indicated the reasonability of the simulation method to determine loading environments and injury characteristics which the patient experienced with knee endoprosthesis during walking.Keywords
Funding Information
- Shenzhen Science and Technology Innovation Commission (JCYJ20160530193728307, 81672176, 51875187, 51621004)
- National Natural Science Foundation of China (JCYJ20160530193728307, 81672176, 51875187, 51621004)
- National Natural Science Foundation of China (JCYJ20160530193728307, 81672176, 51875187, 51621004)
- National Natural Science Foundation of China (JCYJ20160530193728307, 81672176, 51875187, 51621004)
This publication has 15 references indexed in Scilit:
- Investigation of the injury threshold of knee ligaments by the parametric study of car–pedestrian impact conditionsSafety Science, 2014
- Compensation by nonoperated joints in the lower limbs during walking after endoprosthetic knee replacement following bone tumor resectionClinical Biomechanics, 2013
- Individual-specific multi-scale finite element simulation of cortical bone of human proximal femurJournal of Computational Physics, 2013
- A new fracture assessment approach coupling HR-pQCT imaging and fracture mechanics-based finite element modelingJournal of Biomechanics, 2013
- Dynamic finite element knee simulation for evaluation of knee replacement mechanicsJournal of Biomechanics, 2012
- Combined musculoskeletal dynamics/structural finite element analysis of femur physiological loads during walkingMultidiscipline Modeling in Materials and Structures, 2010
- Electromyographic assessment of Gait function following limb salvage procedures for bone sarcomaJournal of Electromyography and Kinesiology, 2010
- Biomechanical evaluation of proximal tibia behaviour with the use of femoral stems in revision TKA: An in vitro and finite element analysisClinical Biomechanics, 2010
- Adjuvant and neoadjuvant chemotherapy for osteosarcoma of the extremities: 27 year experience at Rizzoli Institute, ItalyEuropean Journal of Cancer, 2005
- Development of An Accurate Three-dimensional Finite Element Knee ModelComputer Methods in Biomechanics and Biomedical Engineering, 2002