Enhancing bioreactor arrays for automated measurements and reactive control with ReacSight
Preprint
Abstract
New small-scale, low-cost bioreactor designs provide researchers with exquisite control of environmental parameters of microbial cultures over long durations, allowing them to perform sophisticated, high-quality experiments that are particularly useful in systems biology, synthetic biology and bioengineering. However, existing setups are limited in their automated measurement capabilities, primarily because sensitive and specific measurements require bulky, expensive, stand-alone instruments (for example, most single-cell resolved measurements require a cytometer or a microscope). We present here ReacSight, a generic and flexible strategy to enhance multi-bioreactor platforms for automated measurements and reactive experiment control. We use ReacSight to assemble a platform for single-cell resolved characterization and reactive optogenetic control of parallel yeast continuous cultures. We demonstrate its usefulness by achieving parallel real-time control of gene expression with light in different bioreactors and by exploring the relationship between fitness, nutrient scarcity and cellular stress density using highly-controlled and informative competition assays.Keywords
All Related Versions
- Published version: Nature Communications, 13 (1), 1.
This publication has 35 references indexed in Scilit:
- A Low Cost, Customizable Turbidostat for Use in Synthetic Circuit CharacterizationACS Synthetic Biology, 2014
- Dynamic characterization of growth and gene expression using high-throughput automated flow cytometryNature Methods, 2014
- Real-time optogenetic control of intracellular protein concentration in microbial cell culturesIntegrative Biology, 2014
- Evolutionary paths to antibiotic resistance under dynamically sustained drug selectionNature Genetics, 2011
- In silico feedback for in vivo regulation of a gene expression circuitNature Biotechnology, 2011
- Light-based feedback for controlling intracellular signaling dynamicsNature Methods, 2011
- BiP Binding to the ER-Stress Sensor Ire1 Tunes the Homeostatic Behavior of the Unfolded Protein ResponsePLOS Biology, 2010
- Measuring the activity of BioBrick promoters using an in vivo reference standardJournal of Biological Engineering, 2009
- Directed evolution of antibody fragments with monovalent femtomolar antigen-binding affinityProceedings of the National Academy of Sciences, 2000
- TAT1 Encodes a Low-Affinity Histidine Transporter inSaccharomyces cerevisiaeBiochemical and Biophysical Research Communications, 1998