Abstract
Background and objective Early diagnosis of chronic obstructive pulmonary disease (COPD) in primary care settings is difficult to achieve chiefly due to lack of availability of spirometry. This study estimated the prevalence of airflow limitation among chronic smokers using a handheld spirometer in this setting. Methods This is a cross-sectional study performed on consecutive patients who were 40 years old with 10 pack-years smoking history. Face-to-face interviews were carried out to obtain demographic data and relevant information. Handheld spirometry was performed according to a standard protocol using the COPd-6 device (Model 4000, Vitalograph, Ennis, Ireland) in addition to standard spirometry. Airflow limitation was defined as ratio of forced expiratory volume in 1s (FEV1)/forced expiratory volume in 6s <0.75 (COPd-6) or FEV1/forced vital capacity 65 years (odds ratio (OR) 3.732 95% confidence interval (CI): 1.100-1.280), a history of bad health' (OR 2.524, 95% CI: 1.037-6.142) and low to normal body mass index (OR 2.914, 95% CI: 1.191-7.190). Conclusions In a primary care setting, handheld spirometry (COPd-6) found a prevalence of airflow limitation of approximate to 10% in smokers. Patients were older, not overweight and had an ill-defined history of health problems.
Funding Information
  • Universiti Putra Malaysia (9199775)

This publication has 26 references indexed in Scilit: