Pulmonary Vein Isolation With a Novel Multielectrode Radiofrequency Balloon Catheter That Allows Directionally Tailored Energy Delivery
Authors:
- 1 December 2019
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 12 (12) , e007541
Abstract
Background: Balloon catheters facilitate pulmonary vein (PV) isolation, but current technology is limited by either a single ablative element, potentially leading to over-ablation of thin and under-ablation of thick tissue, or prolonged procedure times. Visualized by electroanatomical mapping, a novel compliant radiofrequency balloon catheter with 10 irrigated, flexible electrodes can simultaneously and independently deliver energy. Herein, we evaluated the feasibility, safety, and short-term efficacy of this radiofrequency balloon in a multicenter, single-arm, first-in-human study. Methods: Paroxysmal atrial fibrillation patients underwent PV isolation with the radiofrequency balloon delivered over-the-wire with a deflectable 13.5F sheath. Radiofrequency energy is delivered simultaneously from all electrodes—up to 30 s posteriorly and 60 s anteriorly. Esophageal temperature was monitored in all patients; the esophagus was also mechanically deviated in 10 patients. Results: At 4 sites, 39 patients were treated by 9 operators. The radiofrequency balloon isolated all targeted PVs (152/152), 79.6% with a single application. Electrical reconnection occurred in only 7/150 PVs (4.7%) on adenosine/isoproterenol challenge. Mean procedure, balloon dwell, and fluoroscopy times were 101.6, 40.5, and 17.4 min, respectively. Esophagogastroduodenoscopy revealed asymptomatic esophageal erythema in 5 patients. Phrenic nerve palsy occurred in a patient in whom phrenic pacing was inadvertently omitted. At 3 months, imaging revealed no PV stenosis, and early atrial arrhythmia recurrence occurred in only 10/39 (25.6%) patients. Conclusions: The compliant radiofrequency balloon can directionally tailor energy delivery for efficient, effective, and reasonably safe acute PV isolation. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: ISRCTN 11764506.Keywords
This publication has 15 references indexed in Scilit:
- Gastric hypomotility after second-generation cryoballoon ablation—Unrecognized silent nerve injury after cryoballoon ablationHeart Rhythm, 2017
- Catheter ablation using the third-generation cryoballoon provides an enhanced ability to assess time to pulmonary vein isolation facilitating the ablation strategy: Short- and long-term results of a multicenter studyHeart Rhythm, 2016
- Adenosine testing during cryoballoon ablation and radiofrequency ablation of atrial fibrillation: A propensity score–matched analysisHeart Rhythm, 2016
- Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial FibrillationThe New England journal of medicine, 2016
- Impact of Complete Versus Incomplete Circumferential Lines Around the Pulmonary Veins During Catheter Ablation of Paroxysmal Atrial FibrillationCirculation: Arrhythmia and Electrophysiology, 2016
- Pulmonary Vein Isolation Using the Visually Guided Laser BalloonJACC, 2015
- How to Learn Pulmonary Vein Isolation with a Novel Ablation Device: Learning Curve Effects Using the Endoscopic Ablation SystemJournal of Cardiovascular Electrophysiology, 2014
- 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial designJournal of Interventional Cardiac Electrophysiology, 2012
- Visually-Guided Balloon Catheter Ablation of Atrial FibrillationCirculation, 2009
- Balloon catheter ablation to treat paroxysmal atrial fibrillation: What is the level of pulmonary venous isolation?Heart Rhythm, 2008