Averaging Times for Pulse Oximeter Measurements – A Review of Manuscripts Published in the Top Five Sleep Medicine Journals
Open Access
- 1 August 2024
- journal article
- review article
- Published by Taylor & Francis in Nature and Science of Sleep
- Vol. ume 16, 1131-1139
Abstract
Purpose: Clinical management decisions often rely on a patient’s SpO2 level and desaturation rate. Limitations include that measurements depend on the averaging time (AVT) used, which is particularly relevant to sleep medicine, but has yet received little attention. Methods: Cross-sectional review of studies reporting pulse oximeter saturation (SpO2) measurements published in 5 leading sleep medicine journals. All papers published between 2017 and 2023 reporting SpO2 measurements were screened regarding the AVT used. Results: Of 193 papers identified, 151 were included; of these, only 9 studies mentioned the AVT, 4 of these were published in one journal. The AVT ranged from zero (beat-to-beat-mode) to 10s, with 3s being used most often (33.3%), followed by 2s (22.2%). Conclusion: The AVT is only rarely mentioned in sleep medicine papers, despite its influence on sleep study results. Reported AVTs were heterogenous. Further research is warranted to set up guidelines for using or reporting the AVT.Keywords
This publication has 45 references indexed in Scilit:
- LED light can falsify pulse oximetry readings via the stroboscopic effectPhysical and Engineering Sciences in Medicine, 2023
- Light-emitting diode surgical light interference with pulse oximetryBritish Journal of Anaesthesia, 2019
- Improving Pulse Oximetry Accuracy by Removing Motion Artifacts from Photoplethysmograms Using Relative Sensor Motion: A Preliminary Study2013
- Decreased accuracy of pulse oximetry measurements during low perfusion caused by sepsis: is the perfusion index of any value?Intensive Care Medicine, 2006
- Ambulatory blood pressure after therapeutic and subtherapeutic nasal continuous positive airway pressure for obstructive sleep apnoea: a randomised parallel trialThe Lancet, 2002
- Advanced pulse oximeter signal processing technology compared to simple averaging. i. effect on frequency of alarms in the operating roomJournal of Clinical Anesthesia, 1999
- Advanced pulse oximeter signal processing technology compared to simple averaging. II. effect on frequency of alarms in the postanesthesia care unitJournal of Clinical Anesthesia, 1999
- Detection of movement artifact in recorded pulse oximeter saturationEuropean Journal of Pediatrics, 1997
- Arterial oxygen saturation in healthy term neonatesEuropean Journal of Pediatrics, 1996
- Patterns of oxygenation during periodic breathing in preterm infantsEarly Human Development, 1991