Analysis of osseointegration of implants with macrogeometries with healing chambers: a randomized clinical trial
Open Access
- 19 September 2024
- journal article
- research article
- Published by Springer Nature in BMC Oral Health
- Vol. 24 (1) , 1-11
Abstract
To verify the influence of macrogeometry with healing chambers on the osseointegration of dental implants by analyzing implant stability quotient (ISQ) and evaluate the correlation between insertion torque and ISQ insertion with different macrogeometries. In total, 26 implants were installed in the posterior mandible of eight patients with sufficient bone height for the installation of implants measuring 3.5 mm in diameter and 9.0 mm in length. The implants were categorized according to two types of macrogeometry: a test group (GT) with 13 conical implants with healing chambers and a control group (GC) with 13 conical implants with conventional threads. To insert the implants, a bone drilling protocol was used up to a diameter of 3 mm with the last helical bur. The insertion torque of the implants was evaluated, followed by the measurement of ISQ at 0 (T-0), 7 (T-7), 14 (T-14), 21 (T-21), 28 (T-28), and 42 (T-42) days. The mean insertion torque was 43 Ncm in both groups, without a significant difference. Moreover, no significant difference in the ISQ values was found between the groups at different time points (p > 0.05), except at T-7 (GT = 69.87±1.89 and GC = 66.48±4.49; p = 0.01). Although there was no significant difference, ISQ median values were higher in the GT group than GC group at 28 days (GT = 67.98 and GC = 63.46; p = 0.05) and 42 days (GT = 66.12 and GC = 60.33; p = 0.09). No correlation was found between the insertion torque and ISQ insertion (p > 0.05). Furthermore, implants with a 3.5 mm diameter macrogeometry, with or without healing chambers, inserted with a drilling protocol up to 3 mm in diameter of the last helical bur, led to a similar secondary stability, with no difference in ISQ values. Although, implants with healing chamber demonstrates ascending values in the graph of ISQ, having a trend of faster osseointegration than implants without healing chambers. Both macrogeometries provide a similar primary stability to implants. This study was registered retrospectively in ReBec (brazilian registry of clinical trials) under the number RBR-96n5×69, on the date of 19/06/2023.Keywords
This publication has 59 references indexed in Scilit:
- Biomechanical and histological evaluation of four different implant macrogeometries in the early osseointegration process: An in vivo animal studyJournal of the Mechanical Behavior of Biomedical Materials, 2022
- Effect of supplemental acid-etching on the early stages of osseointegration: A preclinical modelJournal of the Mechanical Behavior of Biomedical Materials, 2021
- Comparative Evaluation of Implant Stability, Insertion Torque, and Implant Macrogeometry in Different Bone Densities Using Resonance Frequency AnalysisThe Journal of Contemporary Dental Practice, 2021
- Surface characteristics of dental implants: A reviewDental Materials, 2018
- Proliferation, behavior, and differentiation of osteoblasts on surfaces of different microroughnessDental Materials, 2016
- Implant Surface Material, Design, and OsseointegrationDental Clinics of North America, 2015
- The combined effects of undersized drilling and implant macrogeometry on bone healing around dental implants: an experimental studyInternational Journal of Oral and Maxillofacial Surgery, 2014
- A rank‐based sample size method for multiple outcomes in clinical trialsStatistics in Medicine, 2008
- The importance of the elastic and plastic components of strain in tensile and compressive fatigue of human cortical bone in relation to orthopaedic biomechanics.2006
- The resonance frequencies and mode shapes of dental implants: Rigid body behaviour versus bending behaviour. A numerical approachJournal of Biomechanics, 2006