Retinal image quality with multifocal, EDoF, and accommodative intraocular lenses as studied by pyramidal aberrometry
Authors:
Open Access
- 6 October 2021
- journal article
- research article
- Published by Springer Nature in Eye and Vision
- Vol. 8 (1) , 1-11
Abstract
Background: To study and compare the clinical optical image quality following implantation with different premium IOLs by analysing the point spread function (PSF) Strehl ratio using a pyramidal wavefront sensor (PWS)-based aberrometer. Methods: This study included 194 eyes implanted with: (a) 19 AcrySof SA60AT (control group); (b) 19 Miniwell; (c) 24 LENTIS Mplus LS-313 MF30; d) 33 LENTIS Mplus LS-313 MF15; (e) 17 AkkoLens Lumina; (f) 31 AT LISA Tri 839MP; (g) 20 Precizon Presbyopic; (h) 20 AcrySof IQ PanOptix; (i) 11 Tecnis Eyhance. Main outcome measures were PSF Strehl ratio, PSF Strehl ratio excluding second-order aberrations (PSFw2), total root mean square (RMS), low-order aberration (LOA) and high-order aberration (HOA) RMS measured by PWS aberrometer. Results: AT LISA Tri had the highest PSFw2 Strehl ratio at both 3.0- and 4.0-mm pupil size (0.52 ± 0.14 and 0.31 ± 0.10; P < 0.05), followed by SA60AT (0.41 ± 0.11 and 0.28 ± 0.07) and PanOptix (0.4 ± 0.07 and 0.26 ± 0.04). AT LISA Tri was found to provide a significantly better retinal image quality than PanOptix at both 3.0 mm (P < 0.0001) and 4.0 mm (P = 0.004). Mplus MF15 was found to be significantly better than Mplus MF30 at both 3.0 mm (P < 0.0001) and 4.0 mm (P = 0.002). Total RMS, LOA RMS, HOA RMS, PSF Strehl ratio and PSFw2 varied significantly between the studied groups (P < 0.001). Conclusions: Far distance clinical image quality parameters measured by PWS aberrometer differed significantly according to the technology of the implanted lens. AT LISA Tri, SA60AT and PanOptix showed the highest values of far distance retinal image quality, while the lowest PSFw2 Strehl ratios were displayed by Miniwell, Mplus MF30 and Precizon Presbyopic.Keywords
This publication has 28 references indexed in Scilit:
- Multifocal Intraocular Lenses: Neuroadaptation2014
- Applications of wavefront technologyJournal of Cataract & Refractive Surgery, 2012
- Correlation of Visual Performance With Quality of Life and Intraocular Aberrometric Profile in Patients Implanted With Rotationally Asymmetric Multifocal IOLsJournal of Refractive Surgery, 2012
- Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lensJournal of Cataract & Refractive Surgery, 2011
- Visual acuity comparison of 2 models of bifocal aspheric intraocular lensesJournal of Cataract & Refractive Surgery, 2009
- Clinical comparison of 6 aberrometers Part 2: Statistical comparison in a test groupJournal of Cataract & Refractive Surgery, 2006
- Retinal image quality after microincision intraocular lens implantationJournal of Cataract & Refractive Surgery, 2005
- Clinical comparison of 6 aberrometers. Part 1: Technical specificationsJournal of Cataract & Refractive Surgery, 2005
- Compensation of corneal aberrations by the internal optics in the human eyeJournal of Vision, 2001
- Objective measurement of wave aberrations of the human eye with the use of a Hartmann–Shack wave-front sensorJournal of the Optical Society of America A, 1994