Dynamic Glucose Enhanced Imaging using Direct Water Saturation
Authors:
Preprint
Abstract
Purpose: Dynamic glucose enhanced (DGE) MRI studies employ chemical exchange saturation transfer (CEST) or spin lock (CESL) to study glucose uptake. Currently, these methods are hampered by low effect size and sensitivity to motion. To overcome this, we propose to utilize exchange-based linewidth (LW) broadening of the direct water saturation (DS) curve of the water saturation spectrum (Z-spectrum) during and after glucose infusion (DS-DGE MRI). Methods: To estimate the glucose-infusion-induced LW changes ($\Delta$LW), Bloch-McConnell simulations were performed for normoglycemia and hyperglycemia in blood, gray matter (GM), white matter (WM), CSF, and malignant tumor tissue. Whole-brain DS-DGE imaging was implemented at 3 tesla using dynamic Z-spectral acquisitions (1.2 s per offset frequency, 38 s per spectrum) and assessed on four brain tumor patients using infusion of 35 g of D-glucose. To assess $\Delta$LW, a deep learning-based Lorentzian fitting approach was employed on voxel-based DS spectra acquired before, during, and post-infusion. Area-under-the-curve (AUC) images, obtained from the dynamic $\Delta$LW time curves, were compared qualitatively to perfusion-weighted imaging (PWI). Results: In simulations, $\Delta$LW was 1.3%, 0.30%, 0.29/0.34%, 7.5%, and 13% in arterial blood, venous blood, GM/WM, malignant tumor tissue, and CSF, respectively. In vivo, $\Delta$LW was approximately 1% in GM/WM, 5-20% for different tumor types, and 40% in CSF. The resulting DS-DGE AUC maps clearly outlined lesion areas. Conclusions: DS-DGE MRI is highly promising for assessing D-glucose uptake. Initial results in brain tumor patients show high-quality AUC maps of glucose-induced line broadening and DGE-based lesion enhancement similar and/or complementary to PWI.Keywords
All Related Versions
This publication has 53 references indexed in Scilit:
- Quantitative theory for the longitudinal relaxation time of blood waterMagnetic Resonance in Medicine, 2015
- Natural D‐glucose as a biodegradable MRI relaxation agentMagnetic Resonance in Medicine, 2014
- Dynamic susceptibility contrast MRI with a prebolus contrast agent administration design for improved absolute quantification of perfusionMagnetic Resonance in Medicine, 2013
- Natural D‐glucose as a biodegradable MRI contrast agent for detecting cancerMagnetic Resonance in Medicine, 2012
- Exchange‐mediated contrast agents for spin‐lock imagingMagnetic Resonance in Medicine, 2011
- Spin-locking versus chemical exchange saturation transfer MRI for investigating chemical exchange process between water and labile metabolite protonsMagnetic Resonance in Medicine, 2010
- Direct saturation MRI: Theory and application to imaging brain ironMagnetic Resonance in Medicine, 2009
- Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experimentsMagnetic Resonance in Medicine, 2009
- Modeling tracer kinetics in dynamic Gd‐DTPA MR imagingJournal of Magnetic Resonance Imaging, 1997
- Influence of glycogen on water proton relaxation timesMagnetic Resonance in Medicine, 1986