Balloon-assisted coil embolization and large stent delivery for cerebral aneurysms with a new generation of dual lumen balloons (Copernic 2L)
- 28 July 2017
- journal article
- research article
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 10 (4) , 395-400
Abstract
Introduction Dual coaxial lumen balloon microcatheters through which small stents can be delivered have recently been described. We report a series of a new type of dual lumen balloon catheter with a parallel lumen design enabling enhanced inflation and deflation properties through which larger stents may be deployed, including flow diverters (FD). Methods All aneurysms that were treated with a Copernic 2L (COP2L) dual lumen balloon catheter at our institution between February 2014 and December 2016 were assessed. Patient demographics, aneurysm characteristics, clinical and angiographic follow-up, as well as adverse events were analyzed. Results A total of 18 aneurysms in 16 patients (14 women) were treated with the COP2L. Mean maximal aneurysm diameter was 6.4 mm, mean neck size was 3.3 mm (min 1; max 6.3), and mean aneurysm height/width was 1.1 (min 0.5; max 2.1). The COP2L was used for balloon-remodeled coiling exclusively in 2 aneurysms; coiling and FD stenting in 8; coiling and braided stent delivery in 3; coiling, braided and FD stenting in 1; and FD stenting without coiling in 4 (stenting alone). The rate of Roy–Raymond 1 (complete occlusion) changed from 22% in the immediate postoperative period to 100% at 3 months (mean imaging follow-up 8.2 months). There were three technical complications (3/16, 18.7%), including a perforation and two thromboembolic asymptomatic events that were rapidly controlled with the COP2L. There was no immediate or delayed morbidity or mortality (modified Rankin Scale score 0–1 in 100% of patients). Conclusion The COP2L is a new type of dual lumen balloon catheter that may be useful for balloon and/or stent-assisted coiling of cerebral aneurysms. The same device can be used to deliver stents up to 4.5 mm and to optimize stent/wall apposition or serve as a life-saving tool in case of thromboembolic or hemorrhagic events. Long-term efficacy and safety need to be further assessed with larger case-controlled cohorts.Keywords
This publication has 10 references indexed in Scilit:
- Can we now dispense with DSA in the evaluation of aneurysm occlusion even in the most crucial first follow-up after endovascular treatment?Clinical Neurology and Neurosurgery, 2016
- Stent Retriever Use for Retrieval of Displaced Microcoils: A Consecutive Case SeriesAmerican Journal of Neuroradiology, 2013
- Combined use of a double-lumen remodeling balloon and a low-profile stent in the treatment of intracranial aneurysms (‘remostent’ technique): A technical noteJournal Of Neuroradiology, 2013
- Combined balloon stent technique with the Scepter C balloon and low-profile visualized intraluminal stent for the treatment of intracranial aneurysmsJournal of NeuroInterventional Surgery, 2012
- Balloon remodeling for aneurysm coil embolization with the coaxial lumen Scepter C balloon catheter: initial experience at a high volume centerJournal of NeuroInterventional Surgery, 2012
- Efficacy and Safety of Flow Diversion for Paraclinoid Aneurysms: A Matched-Pair Analysis Compared with Standard Endovascular ApproachesAmerican Journal of Neuroradiology, 2012
- Follow-Up of Coiled Intracranial Aneurysms: Comparison of 3D Time-of-Flight MR Angiography at 3T and 1.5T in a Large Prospective SeriesAmerican Journal of Neuroradiology, 2012
- Use of the Ascent Balloon for a 2-in-1 Remodeling TechniqueOperative Neurosurgery, 2012
- Long-Term Angiographic Recurrences After Selective Endovascular Treatment of Aneurysms With Detachable CoilsStroke, 2003
- Endovascular Treatment of Unruptured AneurysmsStroke, 2001