Perforation of the atrial wall and aortic sinus after closure of an atrial septal defect with an Atriasept occluder: a case report
Open Access
- 25 March 2021
- journal article
- case report
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 16 (1) , 1-5
Abstract
Background: While the perforation of the atrial wall and aortic sinus after closure of an atrial septal defect (ASD) is rare, it’s life-threatening, with rapid progress and high mortality. To the best of our knowledge, 21 similar cases have been reported since 1976. Case presentation: We report a 16-year-old male whose atrial septal defect (ASD) was closed using a 12-mm Amplatzer septal occluder (ASO). Atrial wall and aortic sinus perforation occurred 3 months after transcatheter closure, and the patient was discharged after emergency operation. He was discharged on the 12th postoperative day in good overall condition. Conclusions: With this case report, we want to illustrate that although percutaneous closure of ASD is regarded as a routine procedure, we should not forget the potentially lethal complications, especially cardiac erosion. Therefore, we should carefully evaluate the risk of erosion before surgery, and careful lifelong follow-up is needed.Keywords
All Related Versions
Funding Information
- National Natural Science Foundation of China (81770456)
This publication has 9 references indexed in Scilit:
- 2020 ESC Guidelines for the management of adult congenital heart diseaseEuropean Heart Journal, 2020
- Atrial Septal Defect Sizing and Transcatheter ClosureCardiology, 2019
- A randomized, controlled, multi‐center trial of the efficacy and safety of the Occlutech Figulla Flex‐II Occluder compared to the Amplatzer Septal Occluder for transcatheter closure of secundum atrial septal defectsCatheterization and Cardiovascular Interventions, 2018
- Closure of Secundum Atrial Septal Defects With the AMPLATZER Septal OccluderCirculation: Cardiovascular Interventions, 2017
- Closure of Secundum Atrial Septal Defects by Using the Occlutech Occluder Devices in More Than 1300 Patients: The IRFACODE Project: A Retrospective Case SeriesCatheterization and Cardiovascular Interventions, 2016
- Erosions, erosions, and erosions! Device closure of atrial septal defects: How safe is safe?Catheterization and Cardiovascular Interventions, 2012
- Percutaneous atrial Septal Occluder devices and cardiac erosion: A review of the literatureCatheterization and Cardiovascular Interventions, 2012
- Percutaneous closure of atrial septal defects: immediate and mid-term results.2010
- Erosion by the amplatzer septal occluder: Experienced operator opinions at odds with manufacturer recommendations?Catheterization and Cardiovascular Interventions, 2009