Deep-Learning Generation of Synthetic Intermediate Projections Improves 177Lu SPECT Images Reconstructed with Sparsely Acquired Projections
Authors:
- 28 August 2020
- journal article
- research article
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine
- Vol. 62 (4) , 528-535
Abstract
The aims of this study were to decrease the 177Lu-SPECT acquisition time by reducing the number of projections and to circumvent image degradation by adding deep-learning–generated synthesized projections. Methods: We constructed a deep convolutional U-net–shaped neural network for generation of synthetic intermediate projections (CUSIPs). The number of SPECT investigations was 352 for training, 37 for validation, and 15 for testing. The input was every fourth projection of 120 acquired SPECT projections, that is, 30 projections. The output was 30 synthetic intermediate projections (SIPs) per CUSIP. SPECT images were reconstructed with 120 or 30 projections, or with 120 projections when 90 SIPs were generated from 30 projections (30–120SIPs), using 3 CUSIPs. The reconstructions were performed with 2 ordered-subset expectation maximization (OSEM) algorithms: attenuation-corrected (AC) OSEM, and attenuation, scatter, and collimator response–corrected (ASCC) OSEM. The quality of the SIPs and SPECT images was quantitatively evaluated with root-mean-square error, peak signal-to-noise ratio (PSNR), and structural similarity (SSIM) index metrics. From a Jaszczak SPECT phantom, the recovery and signal-to-noise ratio (SNR) were determined. In addition, an experienced observer qualitatively assessed the SPECT image quality of the test set. Kidney activity concentrations, as determined from the different SPECT images, were compared. Results: The generated SIPs had a mean SSIM value of 0.926 (SD, 0.061). For AC-OSEM, the reconstruction with 30–120SIPs had higher SSIM (0.993 vs. 0.989, P < 0.001) and PSNR (49.5 vs. 47.2, P < 0.001) values than the reconstruction with 30 projections. ASCC-OSEM had higher SSIM and PSNR values than AC-OSEM (P < 0.001). There was a minor loss in recovery for 30–120SIPs, but SNR was clearly improved compared with 30 projections. The observer assessed 27 of 30 images reconstructed with 30 projections as having unacceptable noise levels, whereas the corresponding values were 2 of 60 for 30–120SIPs and 120 projections. Image quality did not differ significantly between 30–120SIPs and 120 projections. The kidney activity concentration was similar between the different projection sets, excepting a minor reduction of 2.5% for ASCC-OSEM 30–120SIPs. Conclusion: Adopting SIPs for sparsely acquired projections considerably recovers image quality and could allow a reduced SPECT acquisition time in clinical dosimetry protocols. Visual AbstractKeywords
This publication has 28 references indexed in Scilit:
- MIRD Pamphlet No. 26: Joint EANM/MIRD Guidelines for Quantitative 177Lu SPECT Applied for Dosimetry of Radiopharmaceutical TherapyJournal of Nuclear Medicine, 2015
- Dosimetry for 177Lu-DKFZ-PSMA-617: a new radiopharmaceutical for the treatment of metastatic prostate cancerEuropean Journal of Nuclear Medicine and Molecular Imaging, 2015
- Quantitative Monte Carlo–Based 90Y SPECT ReconstructionJournal of Nuclear Medicine, 2013
- Individualized Dosimetry of Kidney and Bone Marrow in Patients Undergoing 177Lu-DOTA-Octreotate TreatmentJournal of Nuclear Medicine, 2012
- Quantitative 177 Lu SPECT (QSPECT) imaging using a commercially available SPECT/CT systemCancer Imaging, 2011
- 177Lu‐[DOTA0,Tyr3] octreotate therapy in patients with disseminated neuroendocrine tumors: Analysis of dosimetry with impact on future therapeutic strategyCancer, 2010
- Individualized dosimetry in patients undergoing therapy with 177Lu-DOTA-D-Phe1-Tyr3-octreotateEuropean Journal of Nuclear Medicine and Molecular Imaging, 2009
- Evaluation of quantitative imaging methods for organ activity and residence time estimation using a population of phantoms having realistic variations in anatomy and uptakeMedical Physics, 2009
- Image quality assessment: from error visibility to structural similarityIEEE Transactions on Image Processing, 2004
- Accelerated image reconstruction using ordered subsets of projection dataIEEE Transactions on Medical Imaging, 1994