Utility Grid Interfaced Solar WPS Using PMSM Drive With Improved Power Quality Performance for Operation Under Abnormal Grid Conditions
- 17 December 2019
- journal article
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 56 (2) , 1052-1061
Abstract
Owing to the intermittency issue associated with renewable energy sources, a solar photovoltaic (PV) array fed grid interfaced encoder-less permanent magnet synchronous motor (PMSM) based solar water pumping (SWP) system is presented in this work. The grid integration enables a continuous water flow regardless of available solar insolation. However, it has been observed that the grids in developing and underdeveloped countries are mostly weak. Moreover, as SWP systems are typically established at remote locations, which are generally the grid radial ends, therefore, prone to various grid abnormalities. Such abnormalities affect the SWP system performance. Therefore, a hybrid multi-resonant generalized integrator-frequency locked loop (HMRGI-FLL) control structure is presented in this work to deal with the abnormalities in grid voltage and makes the SWP system operational even under weak grid condition. The proposed structure not only rejects the DC-offset but it also eliminates the dominant lower order harmonic with its selective harmonic elimination capability. A boost converter is used on the grid side to facilitate the power transfer from the grid. In condition of grid failure, the output water flow is regulated in accordance with available solar insolation. The speed of the PMSM, is regulated using sensor-less vector control. Performance of proposed system is experimentally validated using a laboratory prototype under varying solar insolation, during grid failure, during voltage sag, voltage swell and distorted grid voltage conditions.Keywords
Funding Information
- JC Bose (RP03128)
- DST (RP03222)
This publication has 21 references indexed in Scilit:
- Power Quality Improvement of Grid-Connected DC Microgrids Using Repetitive Learning-Based PLL Under Abnormal Grid ConditionsIEEE Transactions on Industry Applications, 2017
- An Improved Delayed Signal Cancellation PLL for Fast Grid Synchronization Under Distorted and Unbalanced Grid ConditionIEEE Transactions on Industry Applications, 2017
- An Improved Flux Observer for Field-Oriented Control of Induction Motors Based on Dual Second-Order Generalized Integrator Frequency-Locked LoopIEEE Journal of Emerging and Selected Topics in Power Electronics, 2016
- An Improved Second-Order Generalized Integrator Based Quadrature Signal GeneratorIEEE Transactions on Power Electronics, 2016
- An Integrated Control Algorithm for a Single-Stage PV Pumping System Using an Open-End Winding Induction MotorIEEE Transactions on Industrial Electronics, 2015
- Increasing the efficiency of motor-pump systems using a vector controlled drive for PMSM application2014
- Strategy of energy control in PVP/battery water pumping system2014
- ANFIS-Based Control of a Grid-Connected Hybrid System Integrating Renewable Energies, Hydrogen and BatteriesIEEE Transactions on Industrial Informatics, 2013
- Adaptive Vectorial Filter for Grid Synchronization of Power Converters Under Unbalanced and/or Distorted Grid ConditionsIEEE Transactions on Industrial Electronics, 2013
- A Three-Phase Adaptive Notch Filter-Based Approach to Harmonic/Reactive Current Extraction and Harmonic DecompositionIEEE Transactions on Power Electronics, 2009