Proposed Methodology for Correcting Fourier-Transform Infrared Spectroscopy Field-of-View Scene-Change Artifacts
Open Access
- 17 January 2026
- journal article
- research article
- Published by MDPI AG in Remote Sensing
- Vol. 18 (2) , 317
Abstract
Fourier-transform spectrometers are widely used for spectral measurements. Changes in the field of view during measurement introduce oscillations into the measured spectra known as scene-change artifacts. Field-of-view changes also introduce uncertainty about which target the measured spectrum represents. Though scene-change artifacts are often present in dynamic data, their significance is disputed in the current literature. This work presents a theoretical framework and experimental validation for scene-change artifacts. Field-of-view changes introduce variable interferogram offsets, which standard processing techniques assume are constant. The error between the interferogram offset and its estimate is Fourier-transformed, yielding scene-change artifacts, often confused with noise, in the calibrated spectrum. Previous theoretical models ignored the effect of the interferogram offset in generating SCAs, leading to an underestimation of the scene-change artifact significance. Smooth offset correction removes these artifacts by estimating the variable interferogram offset using locally weighted scatter-plot smoothing. Updating the interferogram offset estimate resulted in the same accuracy expected for static conditions. The resulting spectra resemble the zero path difference spectra, similar to earlier theoretical predictions. These results indicate that Fourier-transform spectroscopy accuracy with variable scenes can be significantly improved with minor modifications to data processing.Keywords
Funding Information
- the National Nuclear Security Agency (89233123SNA000426)
This publication has 29 references indexed in Scilit:
- Recombobulate correction method for oscillating scene change artifacts in longwave infrared Fourier transform spectroscopy spectraApplied Optics, 2025
- A quantitative framework for selecting and validating food web indicatorsEcological Indicators, 2018
- Effects of zero-filling and apodization on spectral integrals in discrete Fourier-transform spectroscopy of noisy dataJournal of Magnetic Resonance, 2006
- Impact of scene changes during data acquisition in Fourier spectroscopyJournal of Quantitative Spectroscopy and Radiative Transfer, 2005
- Radiometric errors in complex Fourier transform spectrometryApplied Optics, 2003
- Infrared signatures from bomb detonationsInfrared Physics & Technology, 2003
- A review of spaceborne infrared Fourier transform spectrometers for remote sensingReview of Scientific Instruments, 1995
- Radiometric calibration of IR Fourier transform spectrometers: solution to a problem with the High-Resolution Interferometer SounderApplied Optics, 1988
- Apodization effects in Fourier transform infrared difference spectraRevue de Physique Appliquée, 1986
- Auxiliary computation for Fourier spectrometryInfrared Physics, 1967