Error Analysis of the Radiative Power Determined From Flux Distributions Measured With a Camera in a Xe Arc Lamp-Based Solar Simulator
Author:
- 4 October 2012
- journal article
- research article
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 134 (4) , 044501
Abstract
The CCD camera-based flux measurement at Paul Scherrer Institute's (PSI) high flux solar simulator (HFSS) is influenced by a spatially variable spectrum of the concentrated radiation characteristic for arc lamp-based solar simulators. This results in a substantial error in the radiative power determined by integration of the flux distribution. This systematic error is assessed by numerically modeling the response of the CCD camera in use. Measured spectra of concentrated radiation obtained at different points in the flux distribution, measured transmission characteristics of all optical elements, and published data for the spectral sensitivity of the CCD chip are applied in the model. The response of a water calorimeter is used as baseline case. It is shown that the magnitude of the error depends strongly on the region analyzed, i.e., on aperture size, on the wavelength band analyzed, and, unfortunately, also on the number of lamps in operation. A relative error in the range of 10–30% is observed if an aperture with 1 cm in diameter covering the region of peak concentration is considered. It will be shown that the error arises due to the fact that a photon counter (CCD camera) is used to determine the thermal power.Keywords
This publication has 9 references indexed in Scilit:
- Spectral Characterization of PSI’s High-Flux Solar SimulatorJournal of Solar Energy Engineering, 2011
- Design of a New 45 kWe High-Flux Solar Simulator for High-Temperature Solar Thermal and Thermochemical ResearchJournal of Solar Energy Engineering, 2011
- A Novel 50kW 11,000 suns High-Flux Solar Simulator Based on an Array of Xenon Arc LampsJournal of Solar Energy Engineering, 2006
- High-heat-flux sensor calibration using calorimetryMetrologia, 2004
- Calibration corrections of solar tower flux density measurementsEnergy, 2004
- Systematic error in the measurement of very high solar irradianceSolar Energy Materials and Solar Cells, 2003
- Comparative Measurements of Different Solar Flux Gauge TypesJournal of Solar Energy Engineering, 2001
- Two Blackbody Radiometers of High AccuracyApplied Optics, 1970
- An Instrument for the Direct Measurement of Intense Thermal RadiationReview of Scientific Instruments, 1953