Perfusion bioreactors have shown great promise for tissue engineering applications providing a homogeneous and consistent distribution of nutrients and flow‐induced shear stresses throughout tissue‐engineered constructs. However, non‐uniform fluid‐flow profiles found in the perfusion chamber entrance region have been shown to affect tissue‐engineered construct quality characteristics during culture. In this study a whole perfusion and construct, three dimensional (3D) computational fluid dynamics approach was used in order to optimize a critical design parameter such as the location of the regular pore scaffolds within the perfusion bioreactor chamber. Computational studies were coupled to bioreactor experiments for a case‐study flow rate. Two cases were compared in the first instance seeded scaffolds were positioned immediately after the perfusion chamber inlet while a second group was positioned at the computationally determined optimum distance were a steady state flow profile had been reached. Experimental data showed that scaffold location affected significantly cell content and neo‐tissue distribution, as determined and quantified by contrast enhanced nanoCT, within the constructs both at 14 and 21 days of culture. However, gene expression level of osteopontin and osteocalcin was not affected by the scaffold location. This study demonstrates that the bioreactor chamber environment, incorporating a scaffold and its location within it, affects the flow patterns within the pores throughout the scaffold requiring therefore dedicated optimization that can lead to bone tissue engineered constructs with improved quality attributes. Biotechnol. Bioeng. 2014;111: 2560–2570.Keywords
Funding Information
- Fonds Wetenschappelijk Onderzoek (G.0982.11N)
This publication has 47 references indexed in Scilit:
- Validation of a PicoGreen-Based DNA Quantification Integrated in an RNA Extraction Method for Two-Dimensional and Three-Dimensional Cell CulturesTissue Engineering Part C: Methods, 2012
- Mechanisms of ectopic bone formation by human osteoprogenitor cells on CaP biomaterial carriersBiomaterials, 2012
- Multi-Level Factorial Analysis of Ca 2+ /P i Supplementation as Bio-Instructive Media for In Vitro Biomimetic Engineering of Three-Dimensional Osteogenic HybridsTissue Engineering Part C: Methods, 2012
- Probing the Osteoinductive Effect of Calcium Phosphate by Using an In Vitro Biomimetic ModelTissue Engineering Part A, 2011
- In vitro generated extracellular matrix and fluid shear stress synergistically enhance 3D osteoblastic differentiationProceedings of the National Academy of Sciences, 2006
- Modeling evaluation of the fluid‐dynamic microenvironment in tissue‐engineered constructs: A micro‐CT based modelBiotechnology and Bioengineering, 2006
- Prediction of the micro-fluid dynamic environment imposed to three-dimensional engineered cell systems in bioreactorsJournal of Biomechanics, 2006
- Quantitative microcomputed tomography analysis of mineralization within three‐dimensional scaffolds in vitroJournal of Biomedical Materials Research Part A, 2004
- Technical Note: Design of a Flow Perfusion Bioreactor System for Bone Tissue-Engineering ApplicationsTissue Engineering, 2003
- Fluid flow increases mineralized matrix deposition in 3D perfusion culture of marrow stromal osteoblasts in a dose-dependent mannerProceedings of the National Academy of Sciences, 2002