Effect of improved navigation performance on the accuracy of implant placement in total hip arthroplasty with a CT-based navigation system
Authors:
- 2 April 2018
- journal article
- research article
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 21 (3) , 340-347
Abstract
A computed tomography (CT)-based navigation system is one of the support tools to place implant with appropriate alignment and position in total hip arthroplasty (THA). To determine whether the higher performance of the navigation would further improve the accuracy of implant placement in the clinical setting, we retrospectively compared the navigation accuracy of two different versions of a navigation system. The newer version of the navigation system had an upgraded optical sensor with superior positional accuracy. Navigation accuracy, defined as differences between postoperative measurements on CT images and intraoperative records on the navigation system, of 49 THAs performed with the newer version of the navigation system was compared with that of 49 THAs performed with the older version. With the newer version, the mean absolute accuracy (95% limits of agreement) of implant alignment was 1.2° (± 3.3°) for cup inclination, 1.0° (± 2.4°) for cup anteversion, 2.0° (± 4.9°) for stem anteversion, and 1.1° (± 2.4°) for stem valgus angle. The accuracy of the implant position was 1.5 mm (± 3.1 mm), 1.3 mm (± 3.0 mm), and 1.5 mm (± 3.1 mm) for cup x-, y-, and z-axes, respectively, 1.6 mm (± 3.2 mm), 1.4 mm (± 2.9 mm), and 1.5 mm (± 2.7 mm) for stem x-, y-, and z-axes, respectively, and 2.4 mm (± 4.5 mm) for leg length discrepancy. The values for the newer version were significantly more accurate with less variation compared to those of the older version. With upgraded navigation performance, more accurate implant placement was demonstrated in the clinical setting.Keywords
This publication has 39 references indexed in Scilit:
- Effect of CT slice thickness on accuracy of implant positioning in navigated total hip arthroplastyComputer Aided Surgery, 2010
- Accuracy of acetabular cup placement in computer-assisted, minimally-invasive THR in a lateral decubitus positionInternational Orthopaedics, 2010
- Accuracy of Computer Navigation for Acetabular Component Placement in THAClinical Orthopaedics and Related Research, 2010
- Comparison of navigation accuracy in THA between the mini‐anterior and ‐posterior approachesThe International Journal of Medical Robotics and Computer Assisted Surgery, 2008
- Navigated non-image-based positioning of the acetabulum during total hip replacementInternational Orthopaedics, 2007
- Imageless navigation for insertion of the acetabular component in total hip arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2006
- Stability and leg length equality in total hip arthroplastyThe Journal of Arthroplasty, 2003
- Accuracy Evaluation of Surface-Based Registration Methods in a Computer Navigation System for Hip Surgery Performed Through a Posterolateral ApproachComputer Aided Surgery, 2001
- Accuracy Evaluation of a CAS System: Laboratory Protocol and Results with 6D Localizers, and Clinical Experiences in OtorhinolaryngologyComputer Aided Surgery, 2001
- Accuracy evaluation of surface-based registration methods in a computer navigation system for hip surgery performed through a posterolateral approachComputer Aided Surgery, 2001