Elimination of Herpes Simplex Virus-2 and Epstein-Barr Virus With Seraph 100 Microbind Affinity Blood Filter and Therapeutic Plasma Exchange: An Explorative Study in a Patient With Acute Liver Failure
Authors:
Open Access
- 11 August 2022
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Explorations
- Vol. 4 (8) , e0745
Abstract
OBJECTIVES: Herpes simplex virus (HSV)-2 is a rare cause of hepatitis that can lead to acute liver failure (ALF) and often death. The earlier the initiation of acyclovir treatment the better the survival. With regard to ALF, controlled randomized data support the use of therapeutic plasma exchange (TPE) both as bridge to recovery or transplantation—possibly by modulating the systemic inflammatory response and by replacing coagulation factors. Seraph 100 Microbind Affinity Blood Filter (Seraph; Ex Thera Medical, Martinez, CA), a novel extracorporeal adsorption device, removes living pathogens by binding to a heparin-coated surface was shown to efficiently clear HSV-2 particles in vitro. Here, we tested the combination of Seraph with TPE to reduce a massive HSV-2 viral load to reach a situation in that liver transplantation would be feasible. DESIGN: Explorative study. SETTING: Academic tertiary care transplant center. PATIENT: Single patient with HSV-2–induced ALF. INTERVENTIONS: TPE + Seraph 100 Microbind Affinity Blood Filter. MEASUREMENTS AND MAIN RESULTS: We report Seraph clearance data of HSV-2 and of Epstein-Barr virus (EBV) in vivo as well as total viral elimination by TPE. Genome copies/mL of HSV-2 and EBV in EDTA plasma were measured by polymerase chain reaction every 60 minutes over 6 hours after starting Seraph both systemically and post adsorber. Also, HSV-2 and EBV were quantified before and after TPE and in the removed apheresis plasma. We found a total elimination of 1.81 × e11 HSV-2 copies and 2.11 × e6 EBV copies with a single TPE (exchange volume of 5L; 1.5× calculated plasma volume). Whole blood clearance of HSV-2 in the first 6 hours of treatment was 6.64 mL/min (4.98–12.92 mL/min). Despite much lower baseline viremia, clearance of EBV was higher 36.62 mL/min (22.67–53.48 mL/min). CONCLUSIONS: TPE was able to remove circulating HSV-2 copies by 25% and EBV copies by 40% from the blood. On the other hand, clearance of HSV-2 by Seraph was clinically irrelevant, but Seraph seemed to be far more effective of removing EBV, implicating a possible use in EBV-associated pathologies, but this requires further study.Keywords
This publication has 10 references indexed in Scilit:
- Interim analysis of the COSA (COVID-19 patients treated with the Seraph® 100 Microbind® Affinity filter) registryNephrology Dialysis Transplantation, 2021
- Acute liver failure due to herpes simplex virus: diagnostic clues and potential role of plasmapheresisMedicine, 2021
- Hemofiltration with the Seraph® 100 Microbind® Affinity filter decreases SARS-CoV-2 nucleocapsid protein in critically ill COVID-19 patientsCritical Care, 2021
- Donor‐derived herpes simplex virus hepatitis in a kidney transplant recipient and review of the literatureTransplant Infectious Disease, 2021
- Heparin 2.0: A New Approach to the Infection CrisisBlood Purification, 2020
- In vitro elimination of anti-infective drugs by the Seraph® 100 Microbind® affinity blood filterClinical Kidney Journal, 2020
- Structure of the herpes simplex virus type 2 C-capsid with capsid-vertex-specific componentNature Communications, 2018
- EASL Clinical Practical Guidelines on the management of acute (fulminant) liver failureJournal of Hepatology, 2017
- Herpes Simplex Virus HepatitisLiver Transplantation, 2007
- Acyclovir pharmacokinetics in plasmapheresis.1990