Abstract
Purpose To describe our experience with exchanging sulcus-fixated single-piece intraocular lens (IOL) with 3-piece IOLs for management of pigmentary glaucoma. Method In this retrospective study, records of patients who underwent sulcus-fixated single-piece IOL exchanged with 3-piece IOLs were retrieved, and demographic and baseline data of patients, type of IOL, pre- and post-IOL exchange BCVA, IOP, number of anti-glaucoma medications, and optic nerve head examination were documented. Baseline and final examinations were analyzed and compared. Results Mean age of the patients was 59 ± 10 years, and 5 (41.6%) were female. Mean interval between primary cataract extraction operation and IOL exchange was 17 ± 5 months. Nine patients received in sulcus implantation of Alcon SA60AT, and three patients had SN60WF model at the end of primary surgery. BCVA changed insignificantly from 0.06 ± 0.06 logMAR to 0.06 ± 0.06 after IOL exchange. (P = 0.22) IOP was controlled in 8 cases (66.6%), but four cases (33.3%) needed glaucoma surgery to further control glaucoma condition. IOP decreased significantly from preoperative 17 ± 3 to 14 ± 1 mmHg postoperatively. Patients with advanced age and higher baseline IOP were more likely to undergo glaucoma surgery after IOL exchange. (P = 0.07 and 0.00, respectively). Conclusion single-piece IOL exchange with 3-piece IOL dramatically decreases pigment release and reduces IOP. Those with advanced age and higher IOP are less likely to respond to IOL exchange and may need glaucoma surgery to control high intraocular pressure.Keywords
This publication has 20 references indexed in Scilit:
- Intermediate term follow-up after a single-piece-acrylic intraocular lens implantation in the ciliary sulcus- a cross-sectional studyBMC Ophthalmology, 2013
- Late-onset secondary pigmentary glaucoma following foldable intraocular lenses implantation in the ciliary sulcus: a long-term follow-up studyBMC Ophthalmology, 2013
- Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical techniqueClinical Ophthalmology, 2010
- Complications of sulcus placement of single-piece acrylic intraocular lensesJournal of Cataract & Refractive Surgery, 2009
- LONG-TERM STABILITY AND VISUAL OUTCOMES OF A SINGLE-PIECE, FOLDABLE, ACRYLIC INTRAOCULAR LENS FOR SCLERAL FIXATIONRetina, 2009
- Direct Measurement of the Ciliary Sulcus Diameter by 35-Megahertz Ultrasound BiomicroscopyOphthalmology, 2007
- Pigment Release and Secondary Glaucoma After Implantation of Single-piece Acrylic Intraocular Lenses in the Ciliary SulcusAmerican Journal of Ophthalmology, 2006
- Single-piece foldable acrylic intraocular lens implantation in the sulcus in eyes with posterior capsule tear during phacoemulsificationJournal of Cataract & Refractive Surgery, 2005
- Practice styles and preferences of ASCRS members—2002 surveyJournal of Cataract & Refractive Surgery, 2003
- Pigment dispersion with elevated intraocular pressure after acrysof intraocular lens implantation in the ciliary sulcusJournal of Cataract & Refractive Surgery, 2001